The long-term biostability of a novel thermoplastic polyurethane elastomer (Elast-Eon 2 80A) synthesized using poly(hexamethylene oxide) (PHMO) and poly(dimethylsiloxane) (PDMS) macrodiols has been studied using an in vivo ovine model. The material's biostability was compared with that of three commercially available control materials, Pellethane 2363-80A, Pellethane 2363-55D and Bionate 55D, after subcutaneous implantation of strained compression moulded flat sheet dumbbells in sheep for periods ranging from 3 to 24 months. Scanning electron microscopy, attenuated total reflectance-Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy were used to assess changes in the surface chemical structure and morphology of the materials. Gel permeation chromatography, differential scanning calorimetry and tensile testing were used to examine changes in bulk characteristics of the materials. The results showed that the biostability of the soft flexible PDMS-based test polyurethane was significantly better than the control material of similar softness, Pellethane 80A, and as good as or better than both of the harder commercially available negative control polyurethanes, Pellethane 55D and Bionate 55D. Changes observed in the surface of the Pellethane materials were consistent with oxidation of the aliphatic polyether soft segment and hydrolysis of the urethane bonds joining hard to soft segment with degradation in Pellethane 80A significantly more severe than that observed in Pellethane 55D. Very minor changes were seen on the surfaces of the Elast-Eon 2 80A and Bionate 55D materials. There was a general trend of molecular weight decreasing with time across all polymers and the molecular weights of all materials decreased at a similar relative rate. The polydispersity ratio, Mw/Mn, increased with time for all materials. Tensile tests indicated that UTS increased in Elast-Eon 2 80A and Bionate 55D following implantation under strained conditions. However, ultimate strain decreased and elastic modulus increased in the explanted specimens of all three materials when compared with their unimplanted unstrained counterparts. The results indicate that a soft, flexible PDMS-based polyurethane synthesized using 20% PHMO and 80% PDMS macrodiols has excellent long-term biostability compared with commercially available polyurethanes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.biomaterials.2004.01.004DOI Listing

Publication Analysis

Top Keywords

bionate 55d
16
elast-eon 80a
12
long-term biostability
8
pdms macrodiols
8
biostability compared
8
materials
8
implantation strained
8
soft flexible
8
flexible pdms-based
8
pellethane 80a
8

Similar Publications

Biomaterials used in cardiosurgical implants and artificial valves that have long-term contact with blood pose a great challenge for researchers due to the induction of thrombogenicity. So far, the assessment of the thrombogenicity of biomaterials has been performed with the use of highly subjective descriptive methods, which has made it impossible to compare the results of various experiments. The aim of this paper was to present a new semi-quantitative method of thrombogenicity assessment based on scanning electron microscope (SEM) images of an adhered biological material deposited on the surfaces of prepared samples.

View Article and Find Full Text PDF

Hemiarthroplasty is often preferred to total arthroplasty as it preserves native tissue; however, accelerated wear of the opposing cartilage is problematic. This is thought to be caused by the stiffness mismatch between the implant and cartilage-bone construct. Reducing the stiffness of the implant by changing the material has been hypothesized as a potential solution.

View Article and Find Full Text PDF

Long-term in vitro hydrolytic stability of thermoplastic polyurethanes.

J Biomed Mater Res A

December 2015

Department of Chemistry, Polymer Science Program, University of Massachusetts Lowell, Lowell, Massachusetts, 01854.

Long-term in vitro stability of thermoplastic polyurethanes (TPUs) was studied for up to 52 weeks in phosphate buffer solution at 37, 55, and 80°C. Water uptake, molecular weights, and tensile properties were measured at regular intervals of 4, 8, 16, 32, and 52 weeks. The rate of molecular weight reduction increased with increasing temperature, and after 52 weeks at 80°C, all commercial polycarbonate (Bionate-55D, Quadrathane-80A, and Chronoflex-80A), poly(dimethylsiloxane) (ElastEon-2A) and polyether (Elasthane-55D) TPUs showed significant (43-51%) molecular weight (Mn ) reduction.

View Article and Find Full Text PDF

The long-term biostability of a novel thermoplastic polyurethane elastomer (Elast-Eon 2 80A) synthesized using poly(hexamethylene oxide) (PHMO) and poly(dimethylsiloxane) (PDMS) macrodiols has been studied using an in vivo ovine model. The material's biostability was compared with that of three commercially available control materials, Pellethane 2363-80A, Pellethane 2363-55D and Bionate 55D, after subcutaneous implantation of strained compression moulded flat sheet dumbbells in sheep for periods ranging from 3 to 24 months. Scanning electron microscopy, attenuated total reflectance-Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy were used to assess changes in the surface chemical structure and morphology of the materials.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!