Objectives: To describe a technique for collecting cancellous bone graft from the proximal humerus in horses.
Study Design: Prospective evaluation of an experimental bone graft collection technique.
Animal Population: Eight horses, 3-15 years, weighing 495-605 kg.
Methods: Horses were anesthetized and positioned in lateral recumbency. The lateral aspect of the proximal humerus was exposed by a 7-10-cm incision extending distally from the greater humeral tubercle, followed by sharp dissection through the omotransversarius muscle and between the infraspinatus and deltoideus muscles. A 12-mm cortical defect was incrementally created in the lateral proximal humerus. Human bone graft harvesting equipment (Acumed, Beaverton, OR) was drilled through this defect to collect a core of cancellous bone. In five horses additional cancellous bone was then collected with conventional instruments. Bone samples were weighed and histologically examined. Horses were monitored and graded for quality of anesthetic recovery, incisional complications, and postoperative lameness.
Results: Total mean (+/-SD) surgical time for harvesting bone with the Acumed system and traditional techniques (n=5) was 38+/-6 minutes (range, 32-47 minutes). Mean cancellous bone weight collected with the Acumed system was 3.6+/-0.8 g (range, 2.0-4.6 g), and cancellous bone collected conventionally was 25.6+/-7.5 g (range, 16.8-34.2 g). Minimal incisional complications or postoperative lameness were observed. Mortality was 12.5%; one horse fractured the operated humerus during anesthetic recovery.
Conclusion: The Acumed system provided limited cancellous bone when used with the technique described. However, the quantity of cancellous bone collected with traditional harvesting instruments was comparable to other sites used in horses. The procedure was associated with minimal postoperative incisional complications or lameness, but because one horse suffered a catastrophic humeral fracture further research is required to assess the effects of this procedure on humeral breaking strength.
Clinical Relevance: Based on the risk of catastrophic fracture, this technique cannot be recommended for use in clinical cases, especially if an unassisted recovery from general anesthesia is planned.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1532-950x.2004.04043.x | DOI Listing |
Materials (Basel)
January 2025
Department of Industrial Engineering, University of Trento, 38123 Trento, Italy.
The metastable β-Ti21S alloy exhibits a lower elastic modulus than Ti-6Al-4V ELI while maintaining high mechanical strength and ductility. To address stress shielding, this study explores the integration of lattice structures within prosthetics, which is made possible through additive manufacturing. Continuous adhesion between the implant and bone is essential; therefore, auxetic bow-tie structures with a negative Poisson's ratio are proposed for regions under tensile stress, while Triply Periodic Minimal Surface (TPMS) structures with a positive Poisson's ratio are recommended for areas under compressive stress.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Department of Spine, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, 100000, China.
Purpose: Lipids increase osteoporosis and fracture risk, yet research on Atherogenic Index of Plasma (AIP), bone mineral density declines (BMD), and trabecular bone score (TBS) is limited. This study examined the relationships between AIP, TBS, and BMD in American adults using the National Health and Nutrition Examination Survey (NHANES) data, including the effect of obesity.
Methods: Based on data from 3,162 Americans, multivariable logistic regression and a generalized additive model (GAM) were used to analyze AIP, BMD, and TBS.
ACS Appl Mater Interfaces
January 2025
Process Engineering Division, CSIR-Central Electrochemical Research Institute, Karaikudi, Tamilnadu 630003, India.
The present study aims to analyze the thermal regulation of the Ce/Ce ratio on the nanonetwork titania layer over the titanium (Ti) surface developed by the alkali-mediated surface modification approach. The effect of sequential heat treatment from 200 to 800 °C was evaluated for its surface characteristics such as morphology, phase formation, roughness, hardness, hydrophilicity, etc. Surface oxidation by temperatures up to 600 °C demonstrated a progressive increase in the Ce (CeO) content with a rutile TiO network layer over the Ti surface.
View Article and Find Full Text PDFJ Craniofac Surg
January 2025
Division of Plastic and Reconstructive Surgery, The Warren Alpert Medical School of Brown University.
Background: Cranial defects from trauma, surgery, or congenital conditions require precise reconstruction to restore cranial vault integrity. Autogenous calvarial grafts are preferred for their histocompatibility and biomechanical properties, but their success depends on a well-developed diploic space. Although prior studies have described overall skull thickness development, less is known about how diploic thickness changes through adulthood.
View Article and Find Full Text PDFInt Dent J
January 2025
Department of Prosthodontics, Dalian Stomatological Hospital, Dalian, China. Electronic address:
Introduction And Aims: Implantation of the posterior maxilla with insufficient bone height faces challenges. Studies have shown that the use of ultrashort implants can avoid additional damage. This finite element analysis study aimed to evaluate the impacts of different lengths of ultrashort implants and three surgical approaches on stress, strain, and displacement in the posterior maxilla with varying bone heights.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!