A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Three-dimensional orthotopic tissue reconstruction with a free, prefabricated high-density porous polyethylene implant flap]. | LitMetric

Background: We investigated the appropriateness of the implant to be used in free-tissue transfers in a rabbit model in which a full-thickness skin graft was wrapped around a prefabricated high-density porous polyethylene implant.

Methods: In ten New Zealand white rabbits, high-density porous polyethylene implants (Medpor), 10x15x3 mm in size, were bilaterally placed and anchored underneath the superficial inferior epigastric artery and vein pedicle under anesthesia. The flaps were prefabricated through vascular induction. Eight weeks later, the flaps were wrapped by a full-thickness postauricular skin graft, following orthotopic transplantation. Two weeks after grafting, full-thickness biopsy samples were obtained from the distal one-third of the implants and stained with hematoxylin-eosin and Masson trichrome for histologic examination.

Results: Graft compliance was observed in all the implants. Histologic sections showed rich fibro-neovascular tissue, neovascularization, and development of connective tissue cells. There were very few polymorphonuclear cells. No signs of inflammation were observed.

Conclusion: Prefabrication of the high-density porous polyethylene implant under the superficial inferior epigastric artery and vein results in sufficient conditions for its use in free transfers.

Download full-text PDF

Source

Publication Analysis

Top Keywords

high-density porous
16
porous polyethylene
16
prefabricated high-density
8
polyethylene implant
8
skin graft
8
superficial inferior
8
inferior epigastric
8
epigastric artery
8
artery vein
8
[three-dimensional orthotopic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!