Objectives: Compared with other non-invasive methods for diagnosing coronary artery disease (CAD), myocardial perfusion imaging (MPI) suffers from some lack of specificity, especially in patients with a small heart. Allowing the assessment of perfusion on end diastolic images instead of summed images, gated single photon emission computed tomography (SPECT) constitutes an attractive method for increasing the accuracy of MPI. Scatter correction, known to improve image contrast, might also be interesting. The present study aimed at comparing scatter corrected to uncorrected gated MPI for CAD diagnosis.

Methods: The results for 100 patients referred for gated 99mTc sestamibi SPECT were analysed. They were divided into two subgroups according to their end systolic volume (ESV) measured by QGS analysis (group A, ESV > or =30 ml, n=65; group B, ESV <30 ml, n=35). For each patient, a total defect score (TDS) was quantified on four polar maps (uncorrected and scatter corrected, summed, and uncorrected and scatter corrected, end diastolic). The optimal TDS separating non-CAD from CAD patients was calculated by analysis of the receiver operating characteristic (ROC) curve for the four data sets, using the coronary angiogram as a 'gold standard'.

Results: In the whole patient population, the accuracy of the uncorrected data was 67% for the end diastolic images and 71% for the summed images (sensitivity, 66% and 70%; specificity, 71% and 79%, respectively). After scatter correction, the accuracy did not change for the end diastolic data (accuracy, 67%; sensitivity, 63%; specificity, 93%) and increased to 74% for the summed data (sensitivity, 73%; specificity, 79%). In group A, the uncorrected data were 72% accurate for the end diastolic images and 78% for the summed images (sensitivity, 72% and 79%; specificity, 75% and 75%, respectively). After correction, the accuracy of end diastolic images increased to 77% (sensitivity, 77%; specificity, 75%), and did not change for the summed images (accuracy, 78%; sensitivity, 79%; specificity, 75%). In group B, the accuracy of uncorrected images amounted to 51% for both end diastolic and summed data (sensitivity, 48% and 40%; specificity, 60% and 80%, respectively). After correction, it increased to 57% for the end diastolic images and to 63% for the summed images (sensitivity, 48% and 64%; specificity, 80% and 60%, respectively).

Conclusions: Despite lower blurring on end diastolic compared with summed images, non-scatter corrected end diastolic data were least accurate for the diagnosis of coronary artery disease in patients with a high prevalence of disease. Scatter correction, by improving the delineation of perfusion defects, increased the accuracy of quantitative MPI for the diagnosis of CAD in a large number of patients, more particularly in those with a small heart.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00006231-200404000-00006DOI Listing

Publication Analysis

Top Keywords

scatter corrected
8
myocardial perfusion
8
coronary artery
8
artery disease
8
group esv
8
head-to-head comparison
4
comparison uncorrected
4
uncorrected scatter
4
corrected summed
4
summed diastolic
4

Similar Publications

Tetramethylammonium (TMA) is a ubiquitous cationic motif in biochemistry, found in the charged choline headgroup of membrane phospholipids and in tri-methylated lysine residues, which modulates histone-DNA interactions and impacts epigenetic mechanisms. TMA interactions with anionic species, particularly carboxylate groups of amino acid residues and extracellular sugars, are of substantial biological relevance, as these interactions mediate a wide range of cellular processes. This study investigates the molecular interactions between TMA and acetate, representing carboxylate-containing groups, using neutron scattering experiments complemented by force fields and molecular dynamics (MD) simulations.

View Article and Find Full Text PDF

Analyzing manure nutrients such as total ammonium nitrogen (NH), dry matter (DM), calcium oxide (CaO), total nitrogen (-N), phosphorus pentoxide (PO), magnesium oxide (MgO), and potassium oxide (KO) helps in fulfilling crop nutritional needs while improving the profitability and a lower risk of pollutants. This study used two Near Infra Red (NIR) spectral datasets of fresh and dried manure. The freshly prepared NHCl, CaO, Ca(OH), PO, MgO, and KO samples were used for spectral signature peak identification and calibration.

View Article and Find Full Text PDF

Development of an image quality evaluation system for bedside chest X-ray images using scatter correction processing.

Radiol Phys Technol

January 2025

Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10 Higashi-ogu, Arakawa, Tokyo, 116-8551, Japan.

In plain radiography, scattered X-ray correction processing (Virtual Grid: VG) is used to estimate and correct scattered rays in images. We developed an objective evaluation system for bedside chest X-ray images using VG and investigated its usefulness. First, we trained the blind/referenceless image spatial quality evaluator (BRISQUE) on 200 images obtained by portable chest radiography.

View Article and Find Full Text PDF

Curcumae Longae Rhizoma (CLRh), Curcumae Radix (CRa), and Curcumae Rhizoma (CRh), derived from the different medicinal parts of the species, are blood-activating analgesics commonly used for promoting blood circulation and relieving pain. Due to their certain similarities in chemical composition and pharmacological effects, these three herbs exhibit a high risk associated with mixing and indiscriminate use. The diverse methods used for distinguishing the medicinal origins are complex, time-consuming, and limited to intraspecific differentiation, which are not suitable for rapid and systematic identification.

View Article and Find Full Text PDF

Multi-Band Scattering Characteristics of Miniature Masson Pine Canopy Based on Microwave Anechoic Chamber Measurement.

Sensors (Basel)

December 2024

Laboratory of Target Microwave Properties, Deqing Academy of Satellite Applications, Deqing 313200, China.

Using microwave remote sensing to invert forest parameters requires clear canopy scattering characteristics, which can be intuitively investigated through scattering measurements. However, there are very few ground-based measurements on forest branches, needles, and canopies. In this study, a quantitative analysis of the canopy branches, needles, and ground contribution of Masson pine scenes in C-, X-, and Ku-bands was conducted based on a microwave anechoic chamber measurement platform.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!