Background And Aim Of The Study: The safety and efficacy of beating-heart valve surgery as a myocardial protection strategy was evaluated in patients with renal failure requiring hemodialysis.

Methods: This was a retrospective review of nine patients (four males, five females; mean age 46.7 years; mean duration of hemodialysis 47 +/- 49 months) who underwent beating-heart valve surgery at the present authors' institution between April 2000 and September 2002.

Results: The mean cardiopulmonary bypass time was 77.2 +/- 8 min. Perioperatively, two patients died (one from sepsis; one from complication of anticoagulation). There were no deaths in the follow up since discharge, with average follow up 18.3 months (range: 9-27 months). Other complications included reintubation for <24 h (one case), AV graft thrombosis (one patient) and stroke (one patient, as mentioned above). There were no new cardiac (including arrhythmia and low cardiac output syndrome) or metabolic complications (including hyperkalemia and fluid overload).

Conclusion: This is the first report of beating-heart valve surgery using simultaneous antegrade and retrograde perfusion with normothermic blood. Despite being small in size, the study demonstrated the safety of this approach in a high-risk population with renal failure requiring hemodialysis. The results suggested a low incidence of complications, and short ICU and hospital stays.

Download full-text PDF

Source

Publication Analysis

Top Keywords

beating-heart valve
12
valve surgery
12
patients renal
8
renal failure
8
failure requiring
8
patients
4
surgery patients
4
requiring hemodialysis
4
hemodialysis background
4
background aim
4

Similar Publications

Mechanical forces continuously provide feedback to heart valve morphogenetic programs. In zebrafish, cardiac valve development relies on heart contraction and physical stimuli generated by the beating heart. Intracardiac hemodynamics, driven by blood flow, emerge as fundamental information shaping the development of the embryonic heart.

View Article and Find Full Text PDF

Purpose: Advancements in minimally invasive technologies to decrease postoperative morbidity and recovery times represent a large opportunity for mitral valve repair operations. However, current technologies are unable to replicate gold standard surgical neochord implantation.

Methods: We developed a novel neochordal repair device, Minimally Invasive Ventricular Anchoring Neochordoplasty (MIVAN), which operates via transcatheter, trans-septal anchoring to the posterior ventricular wall.

View Article and Find Full Text PDF

Merging mixed reality and computational modeling for enhanced visualization of cardiac biomechanics.

Med Eng Phys

December 2024

Department of Engineering, Università degli Studi di Palermo, Viale delle Scienze Ed.8, Palermo, Italy; Department of Research, IRCCS ISMETT via Tricomi, 5, Palermo, Italy. Electronic address:

Mixed reality (MR) has the potential to complement numerical simulations for enhanced post-processing and integrate digital models into the daily clinical practice of healthcare professionals. In complex cardiac anatomies, the decision-making process for bioprosthesis implantation involves the challenging analysis of heart valve distribution, positioning, and sealing. This study proposes a framework to visualize computational modeling results in an immersive environment for comprehensive analysis of the geometric implications of implanted devices on human heart function.

View Article and Find Full Text PDF
Article Synopsis
  • The MitraCut procedure is an innovative technique involving endoscopic scissors to cut the anterior mitral leaflet during transapical transcatheter mitral valve replacement (TA-TMVR) to prevent left ventricular outflow tract (LVOT) obstruction.
  • In a study across six European centers, outcomes were reviewed for 13 high-risk patients who underwent this procedure, showing a high success rate with minimal complications.
  • The findings suggest that the MitraCut procedure is effective at preventing LVOT obstruction, with no postoperative obstructions, a low rate of minor leaks, and no in-hospital or 30-day mortalities among the patients.
View Article and Find Full Text PDF

Background: Redo mitral valve surgery by re-sternotomy approach has challenges such as bleeding and organ injury due to adhesion dissection, sternal bone infection, and poor field of view of mitral valve. On the other hand, redo mitral valve surgery via a right mini-thoracotomy approach appears to address these challenges. We successfully performed a double right mini-thoracotomies approach for mitral valve replacement and pseudoaneurysm repair under the beating-heart condition.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!