A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection of individual microbubbles of ultrasound contrast agents: imaging of free-floating and targeted bubbles. | LitMetric

Rationale And Objectives: During echo examinations with microbubble contrast, individual "dots" of ultrasound reflection can be visualized. To address the question whether these signals represent individual microbubbles, very dilute suspensions of ultrasound contrast agents or individual microbubbles attached to Petri dishes were prepared and studied by ultrasound imaging.

Methods: Microbubble suspensions were diluted in saline and evaluated by a clinical ultrasound imaging system. Microbubble concentration was verified by Coulter counter. Single microbubble preparation on a Petri dish was established by streptavidin-biotin interaction under microscopy control and subjected to ultrasound imaging.

Results: Ultrasound of dilute microbubble dispersions demonstrated distinct white foci; concentration of these sites was consistent with signals from individual microbubbles as determined by Coulter. Individual microbubbles immobilized on polystyrene were also visualized by ultrasound.

Conclusion: Ultrasound medical systems can resolve backscatter signals from individual microbubbles of ultrasound contrast, both in solution and in the targeted immobilized state, implying picogram sensitivity.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.rli.0000115926.96796.75DOI Listing

Publication Analysis

Top Keywords

individual microbubbles
24
ultrasound contrast
12
ultrasound
9
microbubbles ultrasound
8
contrast agents
8
signals individual
8
microbubbles
6
individual
6
microbubble
5
detection individual
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!