The synthesis of a new fluorescein carboxaldehyde asymmetrically substituted on the xanthene (top) ring is reported. This molecule is a key precursor for two of three monofunctionally derivatized fluorescein-based Zn(II) sensors presented in this work. Detailed preparative routes to, and photophysical characterization of, these sensors are described. The sensors are based on the previously reported ZP4 motif (Burdette, S. C.; Frederickson, C. J.; Bu, W.; Lippard, S. J. J. Am. Chem. Soc. 2003, 125, 1778-1787) and incorporate a di(2-picolyl)amine-containing aniline-derivatized ligand framework. By varying the nature of the substituent (X) para to the aniline nitrogen atom, which is responsible for PET quenching of the unbound ZP dye, we investigated the extent to which such electronic tuning might improve the fluorescent properties of asymmetrical ZP sensors. Although a comparison of probes with X = H, F, Cl, OMe reveals that the photophysical behavior of these dyes is not readily predictable, our methodology illustrates the ease with which aniline-based ligands may be linked to fluorescein dyes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ic035158+ | DOI Listing |
Molecular junctions (MJs) are celebrated nanoelectronic devices for mimicking conventional electronic functions, including rectifiers, sensors, wires, switches, transistors, negative differential resistance, and memory, following an understanding of charge transport mechanisms. However, capacitive nanoscale molecular junctions are rarely seen. The present work describes electrochemically (E-Chem) grown covalently attached molecular thin films of 10, 14.
View Article and Find Full Text PDFChem Sci
January 2025
School of Chemistry and Materials Science, Jiangsu Normal University Xuzhou 221116 China
Reactive oxygen species (ROS) play a critical role in regulating various physiological processes. To gain a comprehensive understanding of their distinct functions in different physiological events, it is imperative to detect binary ROS simultaneously. However, the development of the sensing method capable of binary ROS detection remains a significant challenge.
View Article and Find Full Text PDFHardwareX
March 2025
Instituto de Investigacion Astronomico y Aeroespacial Pedro Paulet, Universidad Nacional de San Agustin de Arequipa, 04000, Arequipa, Peru.
Inertial navigation systems (INS) are widely used in commercial aviation, maritime navigation, and unmanned vehicle guidance. However, these systems are often sensitive, costly, and challenging to access. To address these limitations, an open-source, low-cost platform named INS OpenNavSense has been developed.
View Article and Find Full Text PDFJ Mark Access Health Policy
March 2025
BHF Cardiovascular Research Centre, University of Glasgow, Glasgow G12 8TA, UK;
This study illustrates the utility of a mixed-methods approach in assessing the value of an example novel technology-biosensor-integrated self-reporting arteriovenous grafts (smart AVGs). Currently in preclinical development, the device will detect arteriovenous graft stenosis (surveillance-only use case) and treat stenosis (interventional use case). The approach to value assessment adopted in this study was multifaceted, with one stage informing the next and comprised a stakeholder engagement with clinical experts to explore the device's clinical value, a cost-utility analysis (CUA) from a US Medicare perspective to estimate pricing headroom, and an investment model estimating risk-adjusted net present value analysis (rNPVs) to determine commercial viability.
View Article and Find Full Text PDFFront Digit Health
January 2025
Biostatistics and Research Decision Sciences, Merck & Co., Inc., Rahway, NJ, United States.
Background: Current methods of measuring disease progression of neurodegenerative disorders, including Parkinson's disease (PD), largely rely on composite clinical rating scales, which are prone to subjective biases and lack the sensitivity to detect progression signals in a timely manner. Digital health technology (DHT)-derived measures offer potential solutions to provide objective, precise, and sensitive measures that address these limitations. However, the complexity of DHT datasets and the potential to derive numerous digital features that were not previously possible to measure pose challenges, including in selection of the most important digital features and construction of composite digital biomarkers.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!