Purpose: To evaluate the amount of miosis induced by over-minused lenses and to assess subjective reduction of halos following laser in situ keratomileusis (LASIK) with such lenses.

Methods: Part I: Infrared pupil diameter was assessed in 14 patients who had not had ocular surgery. The accommodative/miotic reflex was stimulated with concave trial lenses in -1.00-D increments up to -4.00 D while viewing the 20/40 acuity line. Part II. Subjective halos around a distant light were assessed in 14 patients following LASIK for myopia, with and without a -1.00-D lens over manifest refraction.

Results: Part I: 100%, 79%, and 64% of patients clearly saw the 20/40 line with a -1.00-D lens, -2.00-D lens, and -3.00/-4.00-D lens, respectively. Mean pupil diameter decreased by 0.2 mm with the -1.00-D lens (P = .02), 0.5 mm with the -2.00-D lens (P = .003), 0.9 mm with the -3.00-D lens (P = .008,), and 1.1 mm with the -4.00-D lens (P = .008). Part II: 11 of 14 patients (79%) noticed a decrease in the size of the halo (30% average reduction) when over-minused by -1.00 D.

Conclusions: Pupil diameters and halos decreased with a -1.00-D overcorrection in patients following LASIK. Patients with pupil-dependent night halos after LASIK may benefit from mildly over-minused lenses.

Download full-text PDF

Source
http://dx.doi.org/10.3928/1081-597X-20040301-09DOI Listing

Publication Analysis

Top Keywords

-100-d lens
12
laser situ
8
situ keratomileusis
8
over-minused lenses
8
pupil diameter
8
assessed patients
8
patients lasik
8
lens
8
lens -200-d
8
-200-d lens
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!