A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sirolimus-eluting stents in the canine cerebral vasculature: a prospective, randomized, blinded assessment of safety and vessel response. | LitMetric

AI Article Synopsis

  • The study investigates the safety and effectiveness of sirolimus-eluting stents compared to bare-metal stents in treating intracranial atherosclerosis in dogs.
  • Evidence indicates that sirolimus-eluting stents reduce in-stent stenosis and show no signs of neurotoxicity or vessel damage after implantation.
  • Histological analysis revealed no significant differences in endothelial healing or serious complications between the two types of stents after a follow-up period.

Article Abstract

Object: Use of the sirolimus-eluting stent has led to a reduction of in-stent stenosis following treatment of coronary atherosclerosis, whereas treatment of intracranial atherosclerosis with bare-metal stents results in excessive restenosis rates of approximately 40%. Neurotoxicity effects and vessel injury are unknown in the cerebral vasculature. To assess the safety profile and vascular effects of sirolimus-coated stents, the authors conducted a prospective comparative study in which drug-eluting and bare-metal stents were implanted in the canine basilar artery (BA).

Methods: Sixteen mongrel dogs were randomized (eight animals per group) to receive either bare-metal 1.5 x 8-mm (six-cell) stents or sirolimus-eluting stents of the same dimensions. Interventionists, histopathologists, and histopathology technicians who participated in the study were blinded to the stent characteristics. Stents were implanted in the canine BA. Serial peripheral blood samples were obtained during the 1st week after implantation to determine the time-dependent serum concentration of sirolimus. Follow-up angiographic studies were performed 30 days after stent implantation to assess the effects of stent placement on the BA and brainstem perforating vessels. Explantation of the stent and BA was performed immediately after angiography by using a pressurized formalin fixation procedure. Histological and computer-assisted morphometric analyses of specimens obtained in each animal were performed. Sirolimus could not be detected in peripheral blood samples obtained later than 24 hours posttreatment. On follow-up angiography, all perforating vessels observed on initial angiograms remained patent, and no evidence of parent vessel damage or pseudoaneurysm formation was observed. Explanted vessels and brainstem sections did not demonstrate evidence of histological neurotoxicity, such as gliosis or infarction. No significant differences were found in the time to endothelialization of bare-metal and sirolimus-coated stents. Smooth-muscle cell (SMC) proliferation, the putative agent for restenosis, was lower in animals receiving sirolimus-coated stents (p = 0.003). Additionally, intimal fibrin density was increased in the dogs treated with sirolimus-coated stents (p < 0.0001). Histological evidence of an inflammatory response demonstrated a trend toward a reduced response in the sirolimus group (mean 0.58) compared with the bare-metal group (mean 0.83, p = 0.33).

Conclusions: No neurotoxic effects were observed in the intracranial vessel walls or brainstem tissue in which sirolimus-coated stents were implanted. Compared with bare-metal stents, the sirolimus-coated devices did not impair endothelialization and, furthermore, tended to reduce the proliferation of SMCs. These findings indicate that sirolimus-coated devices may inhibit in-stent stenosis. Further studies with longer-term follow up are required to assess the restenosis rates of sirolimus-coated stents implanted in the intracranial vasculature.

Download full-text PDF

Source
http://dx.doi.org/10.3171/jns.2004.100.4.0688DOI Listing

Publication Analysis

Top Keywords

sirolimus-coated stents
24
stents implanted
16
stents
12
bare-metal stents
12
sirolimus-eluting stents
8
cerebral vasculature
8
in-stent stenosis
8
restenosis rates
8
sirolimus-coated
8
implanted canine
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!