Design and synthesis of labeling reagents (MS probes) for highly sensitive electrospray ionization mass spectrometry and their application to the detection of carbonyl, alcohol, carboxylic acid and primary amine samples.

Anal Sci

Collaboration of Regional Entities for the Advancement of Technological Excellence (CREATE), Kanagawa Academy of Science and Technology, 3-2-1 Sakato, Takatsu-ku, Kawasaki 213-0012, Japan.

Published: March 2004

Novel labeling reagents, called MS probes, which possess a positively charged quaternary amine moiety and can transform a neutral analyte into a charged compound by simply mixing with the analyte and allowing the mixture to stand from several minutes to 30 min at room temperature or while heating to 50 degrees C, were designed and synthesized for the highly sensitive detection of carbonyl, alcohol, carboxylic acid and primary amine samples by electrospray ionization mass spectrometry (ESI-MS). The positively charged products can be detected with high sensitivity in an ESI-MS system, which is the most popular liquid MS instrument. All of the labeled products showed a remarkably large increase in the molecular-ion peak abundance detection sensitivity of over 500-fold at picomolar concentration levels compared to that of unlabeled analytes in an ESI-MS system. These MS probes, used together with liquid MS detection, are widely applicable as a convenient method for the highly sensitive detection of less than picomolar levels of analytes, and therefore greatly enhance the power of ESI-MS analysis.

Download full-text PDF

Source
http://dx.doi.org/10.2116/analsci.20.475DOI Listing

Publication Analysis

Top Keywords

highly sensitive
12
labeling reagents
8
electrospray ionization
8
ionization mass
8
mass spectrometry
8
detection carbonyl
8
carbonyl alcohol
8
alcohol carboxylic
8
carboxylic acid
8
acid primary
8

Similar Publications

Utility of a C-Spirulina Stable Isotope Gastric Emptying Breath Test in Diabetes Mellitus.

Neurogastroenterol Motil

January 2025

Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA.

Background: The carbon-13 spirulina gastric emptying breath test (GEBT) is approved to identify delayed, but not accelerated, gastric emptying (GE). We compared the utility of the GEBT to scintigraphy for diagnosing abnormal GE in patients with diabetes mellitus.

Methods: Twenty-eight patients with diabetes ate a 230-kcal test meal labeled with technetium 99 m and C-spirulina, after which 10 scintigraphic images and breath samples (baseline, 15, 30, 45, 60, 90, 120, 150, 180, 210, and 240 min) were collected on 2 occasions 1 week apart.

View Article and Find Full Text PDF

Electrochemical capacitance-based aptasensor for HER2 detection.

Biomed Microdevices

January 2025

Department of Physics, Faculty of Philosophy, Science and Letter, University of São Paulo, Ribeirão Preto, SP, 14040-901, Brazil.

The overexpression of Human Epidermal Growth Factor Receptor 2 (HER2) protein is specifically related to tumor cell proliferation in breast cancers. Its presence in biological serum samples indicates presence or progression of cancer, becoming a promise biomarker. However, their detection needs a simple and high accuracy platform.

View Article and Find Full Text PDF

Relationships between nutritional status and serum adipokine levels with chemotherapy efficacy in late-stage colorectal cancer patients.

Int J Colorectal Dis

January 2025

Department of Infectious Diseases (Hepatology), Affiliated Hospital of Shaoxing University, 999 Zhongxing South Road, Shaoxing, 312000, Zhejiang, China.

Objective: Colorectal cancer (CRC) is a common cancer, with chemotherapy as its major therapy. Nutritional status (NS) and adipokines implicated in CRC. We explored the impacts of NS indicators (hemoglobin, albumin, and prealbumin) and serum adipokine (visfatin, adiponectin, and resistin) level on chemotherapy efficacy in late-stage CRC patients.

View Article and Find Full Text PDF

Background: While detection of circulating tumor DNA (ctDNA) weeks after surgery is linked to recurrence for other solid tumors, the optimal time point for ctDNA assessment as a prognostic biomarker following chemoradiation for anal cancer is undefined.

Methods: Patients with stages I-III anal cancer treated with chemoradiation between 12/2020-5/2024 were evaluated for HPV ctDNA status at baseline, at the end of chemoradiation, and during surveillance using a droplet digital HPV ctDNA PCR assay targeting HPV E6 and E7 oncogenes for 13 oncogenic HPV types. Median recurrence-free survival (RFS) according to HPV ctDNA status was estimated via Kaplan-Meier and compared using a log-rank test.

View Article and Find Full Text PDF

On the heels of the continuous development of optical fiber sensing technology, optical fiber sensors based on surface plasmon resonance (SPR) have attracted widespread attention. Herein, an SPR sensor based on the six nested anti-resonant fiber (ARF) is designed and analyzed by the finite element method (FEM). All the structural parameters are optimized to achieve high-sensitivity liquid refractive index detection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!