The present study was to evaluate the efficacy of our interleaved T1-T2* weighted imaging for assessing myocardial viability. The left anterior descending coronary artery (LAD) of pig hearts (n = 7) were occluded for 2 h, followed by 1 h reperfusion. After removed from animals, the hearts were perfused in a Langendorff apparatus with a mixture of pig blood and crystalloid solution in 1:1 ratio. T1 relaxation times of the myocardium were measured with a TurboFLASH inversion-recovery sequence. Gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) (0.05 mmol/kg body wt) was then injected as a bolus into the aortic perfusion line. The first pass of the contrast agent through the heart was followed using the interleaved T1-T2* imaging sequence. Once the concentration of the contrast agent was in an equilibrium state, T1 relaxation times were measured again. It was found that the percentage recovery of T2* intensity (PRT2*) at the maximum T1 intensity measured during the first pass of the contrast agent with the interleaved T1-T2* imaging was significantly higher in infarcted myocardium than in normal myocardium. Moreover, the regions showing a high T2* percentage recovery on PRT2* maps matched well with the infarcted myocardium demarcated with triphenyl tetrazolium chloride (TTC) staining. We therefore conclude that infarcted myocardium can be delineated using the interleaved T1-T2* imaging method.

Download full-text PDF

Source
http://dx.doi.org/10.1023/b:caim.0000014045.62343.9bDOI Listing

Publication Analysis

Top Keywords

interleaved t1-t2*
20
contrast agent
12
t1-t2* imaging
12
infarcted myocardium
12
myocardial viability
8
t1-t2* weighted
8
weighted imaging
8
relaxation times
8
pass contrast
8
percentage recovery
8

Similar Publications

Purpose: To develop a framework for simultaneous three-dimensional (3D) mapping of , , and fat signal fraction in the liver at 0.55 T.

Methods: The proposed sequence acquires four interleaved 3D volumes with a two-echo Dixon readout.

View Article and Find Full Text PDF

This study examined proactive control in a two-target task using an endogenous cueing method. Participants identified two target words (T1 then T2) presented in rapid succession. T1 was presented alone or interleaved with a distractor word.

View Article and Find Full Text PDF
Article Synopsis
  • - The study aimed to assess a new imaging technique, 3D-QALAS, for measuring brain tissue properties (T1, T2, and proton density) using different MRI machines without being tied to a specific brand.
  • - Conducted on various 3T MRI systems with healthy volunteers and multiple sclerosis patients, the results showed high accuracy and reproducibility of measurements across different machines and conditions.
  • - The findings indicate that 3D-QALAS can effectively provide consistent brain tissue mapping regardless of the MRI vendor, making it a promising tool for clinical applications.
View Article and Find Full Text PDF

Purpose: Volumetric, high-resolution, quantitative mapping of brain-tissue relaxation properties is hindered by long acquisition times and SNR challenges. This study combines time-efficient wave-controlled aliasing in parallel imaging (wave-CAIPI) readouts with the 3D quantification using an interleaved Look-Locker acquisition sequence with a T preparation pulse (3D-QALAS), enabling full-brain quantitative T , T , and proton density (PD) maps at 1.15-mm isotropic voxels in 3 min.

View Article and Find Full Text PDF

Reproducibility of quantitative ADC, T1, and T2 measurement on the cerebral cortex: Utility of whole brain echo-planar DWI with compressed SENSE (EPICS-DWI): A pilot study.

Eur J Radiol Open

December 2023

Departments of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.

Purpose: To assess the reproducibility of ADC, T1, T2, and proton density (PD) measurements on the cortex across the entire brain using high-resolution pseudo-3D diffusion-weighted imaging using echo-planar imaging with compressed SENSE (EPICS-DWI) and 3D quantification with an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) in normal healthy adults.

Methods: Twelve healthy participants (median age, 33 years; range, 28-51 years) were recruited to evaluate the reproducibility of whole-brain EPICS-DWI and synthetic MRI. EPICS-DWI utilizes a compressed SENSE reconstruction framework while maintaining the EPI sampling pattern.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!