The present study was to evaluate the efficacy of our interleaved T1-T2* weighted imaging for assessing myocardial viability. The left anterior descending coronary artery (LAD) of pig hearts (n = 7) were occluded for 2 h, followed by 1 h reperfusion. After removed from animals, the hearts were perfused in a Langendorff apparatus with a mixture of pig blood and crystalloid solution in 1:1 ratio. T1 relaxation times of the myocardium were measured with a TurboFLASH inversion-recovery sequence. Gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) (0.05 mmol/kg body wt) was then injected as a bolus into the aortic perfusion line. The first pass of the contrast agent through the heart was followed using the interleaved T1-T2* imaging sequence. Once the concentration of the contrast agent was in an equilibrium state, T1 relaxation times were measured again. It was found that the percentage recovery of T2* intensity (PRT2*) at the maximum T1 intensity measured during the first pass of the contrast agent with the interleaved T1-T2* imaging was significantly higher in infarcted myocardium than in normal myocardium. Moreover, the regions showing a high T2* percentage recovery on PRT2* maps matched well with the infarcted myocardium demarcated with triphenyl tetrazolium chloride (TTC) staining. We therefore conclude that infarcted myocardium can be delineated using the interleaved T1-T2* imaging method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1023/b:caim.0000014045.62343.9b | DOI Listing |
Magn Reson Med
December 2024
School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
Purpose: To develop a framework for simultaneous three-dimensional (3D) mapping of , , and fat signal fraction in the liver at 0.55 T.
Methods: The proposed sequence acquires four interleaved 3D volumes with a two-echo Dixon readout.
Conscious Cogn
February 2024
McMaster University, Canada.
This study examined proactive control in a two-target task using an endogenous cueing method. Participants identified two target words (T1 then T2) presented in rapid succession. T1 was presented alone or interleaved with a distractor word.
View Article and Find Full Text PDFMagn Reson Med
May 2024
Department of Radiology, Juntendo University, Tokyo, Japan.
Magn Reson Med
February 2024
Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Purpose: Volumetric, high-resolution, quantitative mapping of brain-tissue relaxation properties is hindered by long acquisition times and SNR challenges. This study combines time-efficient wave-controlled aliasing in parallel imaging (wave-CAIPI) readouts with the 3D quantification using an interleaved Look-Locker acquisition sequence with a T preparation pulse (3D-QALAS), enabling full-brain quantitative T , T , and proton density (PD) maps at 1.15-mm isotropic voxels in 3 min.
View Article and Find Full Text PDFEur J Radiol Open
December 2023
Departments of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
Purpose: To assess the reproducibility of ADC, T1, T2, and proton density (PD) measurements on the cortex across the entire brain using high-resolution pseudo-3D diffusion-weighted imaging using echo-planar imaging with compressed SENSE (EPICS-DWI) and 3D quantification with an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) in normal healthy adults.
Methods: Twelve healthy participants (median age, 33 years; range, 28-51 years) were recruited to evaluate the reproducibility of whole-brain EPICS-DWI and synthetic MRI. EPICS-DWI utilizes a compressed SENSE reconstruction framework while maintaining the EPI sampling pattern.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!