The value of automatic bolus tracking in late-arterial and portal-venous phase imaging of the liver with a multislice CT scanner as compared with fixed time-delay examination in patients without circulatory disturbances is evaluated. For the evaluation of known or suspected liver disease, 98 multiphase contrast-enhanced CT examinations including double late-arterial phase imaging were randomized into either scanning with a scan delay of 30 s from the beginning of contrast material injection or scanning with automatic bolus tracking. Contrast material was injected at 0.07 ml/kg body weight/s over 30 s. Contrast enhancement in each acquisition was measured in the aorta, portal vein, liver, pancreas and hepatocellular carcinomas. The density difference between hepatocellular carcinomas and the hepatic parenchyma was calculated. The mean time to the first-pass acquisition as determined by automatic bolus tracking was 29.6 s. No statistically significant difference was observed between the two groups either in any enhancement in any acquisition or in the lesion-to-liver density difference. The use of automatic bolus tracking in late-arterial and portal-venous phase hepatic CT does not significantly improve the degree of contrast enhancement in the aorta, portal vein, liver and pancreas or lesion-to-liver conspicuity in patients without circulatory disturbances.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-004-2321-5DOI Listing

Publication Analysis

Top Keywords

automatic bolus
20
bolus tracking
20
late-arterial portal-venous
12
portal-venous phase
12
phase imaging
12
patients circulatory
12
circulatory disturbances
12
imaging liver
8
liver multislice
8
multislice scanner
8

Similar Publications

Purpose: Contrast-enhanced CT (CECT) may be performed immediately following microwave liver ablation for assessment of ablative margins. However, practices and protocols vary among institutions. Here, we compare a standardized bolus-tracked biphasic CECT protocol and compare this with a single venous phase fixed delay protocol for ablation zone (AZ) assessment.

View Article and Find Full Text PDF

Purpose: Patient-controlled analgesia (PCA) has been considered for managing cancer pain; however, limited research has been conducted on optimizing continuous infusion rates with PCA. This study aimed to evaluate the efficacy and safety of a method that optimizes background infusion (BI) alongside PCA for titrating intravenous (IV) morphine in managing cancer-related pain.

Methods: Forty-four patients with solid tumors who could not manage pain with oral or transdermal opioid analgesics were randomly assigned in a 1:1 ratio to receive IV morphine through PCA or the conventional method.

View Article and Find Full Text PDF

Recent advancements and future directions in automatic swallowing analysis via videofluoroscopy: A review.

Comput Methods Programs Biomed

February 2025

Edward S. Rogers Department of Electrical and Computer Engineering, Faculty of Applied Science and Engineering, University of Toronto, Toronto, ON, Canada; North York General Hospital, Toronto, ON, Canada. Electronic address:

Article Synopsis
  • Videofluoroscopic swallowing studies (VFSS) are important for understanding how we swallow, but consistency in assessing them can be challenging due to evaluator biases and variable methods.
  • Advances in computer technology, like computer vision and deep learning, are being used to improve the accuracy and efficiency of VFSS analyses.
  • A detailed review of 46 studies highlights these advanced image processing techniques, aiming to address current challenges and suggest future improvements for automated swallowing assessments.
View Article and Find Full Text PDF

Refining Insulin on Board with netIOB for Automated Insulin Delivery.

J Diabetes Sci Technol

August 2024

Division of Endocrinology, Department of Pediatrics, School of Medicine, Stanford University, Stanford, CA, USA.

Automated insulin delivery (AID) systems enhance glucose management by lowering mean glucose level, reducing hyperglycemia, and minimizing hypoglycemia. One feature of most AID systems is that they allow the user to view "insulin on board" (IOB) to help confirm a recent bolus and limit insulin stacking. This metric, along with viewing glucose concentrations from a continuous glucose monitoring system, helps the user understand bolus insulin action and the future "threat" of hypoglycemia.

View Article and Find Full Text PDF

Background: We prospectively assessed the reproducibility of a novel low-dose single-volume dynamic computed tomography (CT) myocardial blood flow measurement technique.

Methods: Thirty-four pairs of measurements were made under rest and stress conditions in 13 swine (54.3 ± 12.

View Article and Find Full Text PDF