A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel method for analysis of TOMROP data. | LitMetric

A novel method for analysis of TOMROP data.

J Magn Reson Imaging

Department of Radiology, School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA.

Published: April 2004

Purpose: To develop an efficient method for extracting maps of the corrected T1 from images generated using the T One by Multiple Read Out Pulses (TOMROP) sequence.

Materials And Methods: An expression is developed for the true T1 in terms of the parameters from a three-parameter fit of the TOMROP data. Solutions of gadodiamide in normal saline with concentrations of 0.0, 0.06, 0.11, 0.23, 0.46, and 0.91 mM were prepared and T1 measurements were performed using both the inversion recovery (IR) and the TOMROP methods. The TOMROP data were analyzed using the proposed technique and the results compared to those from the IR measurements.

Results: The T1 estimates generated from the TOMROP data using the proposed method were consistent with the IR results. However, systematic errors were observed in the T1 estimates when the repetition time was not sufficient for full recovery of axial magnetization. Relaxation times determined using the proposed method were within 1% of the spectroscopiclly determined values for T1 values in the range of 0.28-2.8 seconds when a suitable delay was employed.

Conclusion: The proposed method of analysis was found to yield accurate T1 estimates when the assumptions used in the analysis were not violated.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.20027DOI Listing

Publication Analysis

Top Keywords

tomrop data
16
proposed method
12
method analysis
8
tomrop
6
novel method
4
analysis tomrop
4
data
4
data purpose
4
purpose develop
4
develop efficient
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!