Existing methodology for surface tension measurements based on drop shapes suffers from the shortcoming that it is not capable to function at very low surface tension if the liquid dispersion is opaque, such as therapeutic lung surfactants at clinically relevant concentrations. The novel configuration proposed here removes the two big restrictions, i.e., the film leakage problem that is encountered with such methods as the pulsating bubble surfactometer as well as the pendant drop arrangement, and the problem of the opaqueness of the liquid, as in the original captive bubble arrangement. A sharp knife edge is the key design feature in the constrained sessile drop that avoids film leakage at low surface tension. The use of the constrained sessile drop configuration in conjunction with axisymmetric drop shape analysis to measure surface tension allows complete automation of the setup. Dynamic studies with lung surfactant can be performed readily by changing the volume of a sessile drop, and thus the surface area, by means of a motor-driven syringe. To illustrate the validity of using this configuration, experiments were performed using an exogenous lung surfactant preparation, bovine lipid extract surfactant (BLES) at 5.0 mg/ml. A comparison of results obtained for BLES at low concentration between the constrained sessile drop and captive bubble arrangement shows excellent agreement between the two approaches. When the surface area of the BLES film (0.5 mg/ml) was compressed by about the same amount in both systems, the minimum surface tensions attained were identical within the 95% confidence limits.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/japplphysiol.00089.2003 | DOI Listing |
Adv Sci (Weinh)
December 2024
Department of Materials Science and Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-Ro, Nam-gu, Pohang, 37673, Republic of Korea.
The evaporation of drops on solid surfaces is a ubiquitous natural phenomenon, and their dynamics play a pivotal role in many biological, environmental, and industrial processes. However, the complexity of the underlying mechanisms has largely confined previous studies to liquid drop evaporation under atmospheric conditions. In this study, the first comprehensive investigation of the evaporation dynamics of conducting polymer-containing drops under controlled vacuum environments is presented.
View Article and Find Full Text PDFNanomaterials (Basel)
December 2024
College of Electrical and Power Engineering, Taiyuan University of Technology, Taiyuan 030024, China.
Although understanding the wetting behavior of solid surfaces is crucial for numerous engineering applications, the mechanisms driving the motion of Wenzel drops on rough surfaces remain incompletely clarified. In this study, the contact angle and contact angle hysteresis of Wenzel drops on superhydrophobic surfaces are investigated from a thermodynamic perspective. The free energy of the system is theoretically analyzed, thereby determining the equilibrium contact angle.
View Article and Find Full Text PDFJ Int Soc Prev Community Dent
October 2024
Department of Prosthodontics Dentistry, University of Mosul, Mosul, Iraq.
Aim: This study was conducted to improve the wettability of heat cured acrylic resin by the incorporation of recycled poly methyl methacrylate (PMMA) as well as the assessment of how different aging times affected it.
Materials And Methods: A total of 40 heat cured resin specimens were prepared and randomly divided into: The study and the control groups. Recycled PMMA was added to the study group at 1%, 3%, and 5% concentrations by volume.
J Biomed Mater Res B Appl Biomater
December 2024
Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil.
The adhesion strength of a bacterial strain on a substrate influences colonization and biofilm development, so the biomolecular analysis of this interaction is a step that allows insights into the development of antifouling surfaces. As peri-implantitis is the main cause of failure of implant-supported oral rehabilitations and the dental literature presents gaps in the atomic bacteria/surface interaction, this study aimed to correlate the qualitative variation of roughness, wettability, chemical composition, and electrical potential of Ti-6Al-4V and Ti-35Nb-7Zr-5Ta (TNZT) disks obtained by machining (M) and additive manufacturing (AM) on the colonization and adhesion strength of S. aureus quantified by atomic force microscopy (AFM).
View Article and Find Full Text PDFJ Dairy Sci
January 2025
Food Rheology Laboratory, Department of Food, Bioprocessing and Nutrition Sciences, North Carolina State University, Raleigh, NC 27695; Southeast Dairy Foods Research Center, North Carolina State University, Raleigh, NC 27695. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!