A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A single-step, sensitive flow cytofluorometric assay for the simultaneous assessment of membrane-bound and ingested Candida albicans in phagocytosing neutrophils. | LitMetric

Background: Distinguishing ingested particles from those attached to the cell surface is an essential requirement when performing quantitative studies of phagocytosis. In the present report, we describe a simple, sensitive and reliable flow cytofluorometric method that achieves this goal in a Candida albicans-human neutrophils (PMN) system.

Methods: The assay is based on the observation that the vital dye trypan blue (TB), while quenching the green fluorescence of fluorescein-labeled C. albicans, causes them to fluoresce red. PMN were incubated with fluorescein-labeled yeast particles for the required time. Aliquots of the incubation mixtures were then promptly diluted with an equal volume of a TB solution at pH 4.0, and subsequently analyzed by flow cytometry for green and red fluorescence.

Results: Since TB does not penetrate into the cells, ingested yeasts retain their green fluorescence, while membrane-bound particles display a red fluorescence.

Conclusions: Our fluorescence flow cytometric method enables to simultaneously distinguish, within the leukocyte population, cell subsets with attached and ingested yeast particles. Its major features are: (1) accuracy, sensitivity and reproducibility; (2) no further sample manipulations after completion of phagocytosis; (3) possibility of counting free, attached and internalized yeast particles; and (4) use of a nontoxic reagent (TB).

Download full-text PDF

Source
http://dx.doi.org/10.1002/cyto.a.20014DOI Listing

Publication Analysis

Top Keywords

yeast particles
12
flow cytofluorometric
8
green fluorescence
8
particles
5
single-step sensitive
4
flow
4
sensitive flow
4
cytofluorometric assay
4
assay simultaneous
4
simultaneous assessment
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!