There is an infinity of impedance parameter values, and thus different co-contraction levels, that can produce similar movement kinematics from which the CNS must select one. Although signal-dependent noise (SDN) predicts larger motor-command variability during higher co-contraction, the relationship between impedance and task performance is not theoretically obvious and thus was examined here. Subjects made goal-directed, single-joint elbow movements to either move naturally to different target sizes or voluntarily co-contract at different levels. Stiffness was estimated as the weighted summation of rectified EMG signals through the index of muscle co-contraction around the joint (IMCJ) proposed previously. When subjects made movements to targets of different sizes, IMCJ increased with the accuracy requirements, leading to reduced endpoint deviations. Therefore without the need for great accuracy, subjects accepted worse performance with lower co-contraction. When subjects were asked to increase co-contraction, the variability of EMG and torque both increased, suggesting that noise in the neuromotor command increased with muscle activation. In contrast, the final positional error was smallest for the highest IMCJ level. Although co-contraction increases the motor-command noise, the effect of this noise on the task performance is reduced. Subjects were able to regulate their impedance and control endpoint variance as the task requirements changed, and they did not voluntarily select the high impedance that generated the minimum endpoint error. These data contradict predictions of the SDN-based theory, which postulates minimization of only endpoint variance and thus require its revision.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/jn.00519.2003 | DOI Listing |
A reconfigurable holographic metasurface (HM) with multifunctional modulation of radiation and scattering for conformal applications is designed in this paper. Based on optical holography theory, a holographic conformal modulation mechanism is proposed, and the conformal surface impedance distribution of HM is derived. To illustrate this mechanism, the designed conformal reconfigurable HM is used to demonstrate a series of radiation and scattering modulation functions, with its reconfigurable property enabling dynamic beam control.
View Article and Find Full Text PDFJ Am Chem Soc
January 2025
State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing 211816, China.
Metal-nonaqueous solution interfaces, a key to many electrochemical technologies, including lithium metal batteries, are much less understood than their aqueous counterparts. Herein, on several metal-nonaqueous solution interfaces, we observe capacitances that are 2 orders of magnitude lower than the usual double-layer capacitance. Combining electrochemical impedance spectroscopy, atomic force microscopy, and physical modeling, we ascribe the ultralow capacitance to an interfacial layer of 10-100 nm above the metal surface.
View Article and Find Full Text PDFActa Biomater
January 2025
Department of Biomedical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA. Electronic address:
In injured and diseased tissues, changes in molecular and cellular compositions, as well as tissue architecture, lead to alterations in both physiological and physical characteristics. Notably, the electrical properties of tissues, which can be characterized as bioelectrical impedance (bioimpedance), are closely linked to the health and pathological conditions of the tissues. This highlights the significant role of quantitatively characterizing these electrical properties in improving the accuracy and speed of diagnosis and prognosis.
View Article and Find Full Text PDFAdv Clin Exp Med
January 2025
Clinic of Children's Diseases, Institute of Clinical Medicine, Faculty of Medicine, Vilnius University, Lithuania.
Background: The number of infants born via cesarean section (CS) is increasing globally due to medical and cultural reasons.
Objectives: This study aimed to determine the effect of the mode of delivery on early lung aeration in newborns using electrical impedance tomography (EIT).
Material And Methods: The case-control study was conducted from December 2020 to April 2021.
Front Robot AI
January 2025
School of Metallurgy and Materials, University of Birmingham, Birmingham, United Kingdom.
Introduction: The transition to electric vehicles (EVs) has highlighted the need for efficient diagnostic methods to assess the state of health (SoH) of lithium-ion batteries (LIBs) at the end of their life cycle. Electrochemical Impedance Spectroscopy (EIS) offers a non-invasive technique for determining battery degradation. However, automating this process in industrial settings remains a challenge.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!