3.141.25.1003.141.25.100

A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3124
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Immediate HbA1c results. Performance of new HbA1c system in pediatric outpatient population. | LitMetric

Objective: This study compared the performance of a new device that uses an IA to measure HbA1c in 9 min with a 1-microliter capillary blood sample with AC and CE methods in both nondiabetic and diabetic pediatric patients.

Research Design And Methods: Two hundred seven pediatric subjects (103 nondiabetic, 104 with insulin-dependent diabetes mellitus) had HbA1c measured with the IA method and compared with total GHb values determined by AC and HbA1 by the CE method with the same whole-blood capillary aliquot. Glucose values were also obtained from the same blood samples.

Results: Correlations and regression analyses show excellent correspondence between the three assays. The correlation between the AC and CE methods is 0.98 (P less than 0.001) with a slope of 1.615 +/- 0.0125 and intercept of 4.00 +/- 0.20. The correlation between the IA and AC methods is 0.99 (P less than 0.001) with a slope of 0.608 +/- 0.007 and intercept of 1.326 +/- 0.066. The correlation between the IA and CE methods is 0.97 (P less than 0.001), with a slope of 0.983 +/- 0.018 and intercept of 1.122 +/- 0.153. The average difference and average percentage difference between methods were also significant (P less than 0.001), reflecting the differences in GHb components measured. There was a significant correlation (P less than 0.001) between each method and glucose values (IA r = 0.72, AC r = 0.70, CE r = 0.73). Within-run precision for IA ranged from 1.7 to 3.5% and between-run precision 2.7 to 4.1%.

Conclusions: Study results suggest that the IA method gives extremely accurate and reliable values over the clinical range of interest. The instrument is small, portable, easy to use, and provides information within 9 min for both physicians and patients.

Download full-text PDF

Source
http://dx.doi.org/10.2337/diacare.15.8.1045DOI Listing

Publication Analysis

Top Keywords

correlation methods
12
0001 slope
12
glucose values
8
methods
6
+/-
6
0001
5
hba1c
4
hba1c performance
4
performance hba1c
4
hba1c system
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!