Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To evaluate the diagnostic agreement between quantitative cultures of samples obtained with endotracheal aspiration (ETA) and plugged telescoping catheter (PTC).
Design: Prospective study.
Setting: Medical ICU.
Patients: Hundred thirty-eight episodes of suspected ventilator-associated pneumonia studied in 100 consecutive patients.
Interventions: For each suspected episode of ventilator-associated pneumonia, ETA and PTC were performed consecutively. The agreement between microbiological results obtained from the two techniques was evaluated (kappa statistic test). Pneumonia was diagnosed on a positive culture result of telescoping catheter with the threshold set at 10(3) cfu/ml or more. The cut-off points evaluated for ETA ranged from 10(2 )to 10(6) cfu/ml.
Results: Micro-organisms retrieved by aspiration and telescoping catheter were similar and bacterial counts obtained by the two procedures were well correlated ( r = 0.71 p < 0.001). There was good agreement between positive and negative ETA and PTC specimens (kappa: 0.78) with a diagnostic threshold for ETA of 10(4) cfu/ml. The sensitivity and specificity of ETA for the diagnosis of PTC-confirmed pneumonia were 92% and 85%, respectively. Kappa decreased to 0.48 when the diagnostic threshold was increased to 10(6) cfu/ml.
Conclusions: Quantitative cultures of ETA and PTC tallied for both micro-organisms and counts. The simpler ETA appears adequate for determining the presence of pathogenic organisms in significant concentration in the lower respiratory tract.