Purpose: A comparative treatment planning study has been undertaken between intensity modulated (IM) photon therapy and IM proton therapy (IMPT) in paraspinal sarcomas, so as to assess the potential benefits and limitations of these treatment modalities. In the case of IM proton therapy, plans were compared also for two different sizes of the pencil beam. Finally, a 10% and 20% dose escalation with IM protons was planned, and the consequential organ at risk (OAR) irradiation was evaluated.

Methods And Materials: Plans for 5 patients were computed for IM photons (7 coplanar fields) and protons (3 coplanar beams), using the KonRad inverse treatment planning system (developed at the German Cancer Research Center). IMPT planning was performed assuming 2 different sizes of the pencil beam: IMPT with a beam of full width at half-maximum of 20 mm, and IMPT with a "mini-beam" (IMPT(M), full width at half-maximum = 12 mm). Prescribed dose was 77.4 Gy or cobalt Gray equivalent (CGE) for protons to the gross tumor volume (GTV). Surface and center spinal cord dose constraint for all techniques was 64 and 53 Gy/CGE, respectively. Tumor and OAR dose-volume histograms were calculated. Results were analyzed using dose-volume histogram parameters, inhomogeneity coefficient, and conformity index.

Results: Gross tumor volume coverage was optimal and equally homogeneous with both IM photon and IM proton plans. Compared to the IM photon plans, the use of IM proton beam therapy leads to a substantial reduction of the OAR total integral dose in the low-level to mid-dose level. Median heart, lung, kidney, stomach, and liver mean dose and dose at the 50% volume level were consistently reduced by a factor of 1.3 to 25. Tumor dose homogeneity in IMPT(M) plans was always better than with IMPT planning (median inhomogeneity coefficient, 0.19 vs. 0.25). IMPT dose escalation (to 92.9 CGE to the GTV) was possible in all patients without exceeding the normal-tissue dose limits.

Conclusions: These results suggest that the use of IM photon therapy, when compared to IM protons, can result in similar levels of tumor conformation. IM proton therapy, however, reduces the OAR integral dose substantially, compared to IM photon radiation therapy. As a result, tumor dose escalation was always possible with IM proton planning, within the maximal OAR dose constraints. In IM proton planning, reducing the size of the proton pencil beam (using the "mini-beam") improved the dose homogeneity, but it did not have a significant effect on the dose conformity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijrobp.2003.11.028DOI Listing

Publication Analysis

Top Keywords

proton therapy
16
dose
14
treatment planning
12
pencil beam
12
dose escalation
12
proton
9
intensity modulated
8
modulated photon
8
photon proton
8
therapy
8

Similar Publications

Objectives: Our aim was to systematically review the cost-effectiveness of proton pump inhibitor (PPI) therapies and surgical interventions for gastro-oesophageal reflux disease (GORD).

Design: The study design was a systematic review of economic evaluations.

Data Sources: We searched PubMed, Embase, Scopus, and Web of Science for publications from January 1990 to March 2023.

View Article and Find Full Text PDF

This letter critically evaluates the conclusions drawn by Li et al. (https://doi.org/10.

View Article and Find Full Text PDF

Objective: Ewing sarcoma (EWS) of the mediastinum is extremely rare, with only a few cases reported in the literature. We aimed to gain a better understanding of primary mediastinal EWS, describing patients treated within two international, multicenter, prospective, randomized EWS trials.

Methods: Data from patients with primary mediastinal EWS were retrieved from the database of the EURO-E.

View Article and Find Full Text PDF

Evaluating Neoadjuvant Immunochemotherapeutic Response for Bladder Carcinoma Using Amide Proton Transfer-Weighted MRI.

Acad Radiol

January 2025

Department of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou, 510080, Guangdong, PR China (L.K., B.W., Q.C., L.M., W.C., Y.C., Y.G., H.W.). Electronic address:

Rationale And Objectives: To investigate the feasibility of amide proton transfer-weighted (APTw) and diffusion-weighted MRI in evaluating the response of bladder cancer (BCa) to neoadjuvant immunochemotherapy.

Materials And Methods: From June 2021 to July 2023, participants with pathologically confirmed BCa were prospectively recruited to undergo MRI examinations, including APTw and diffusion-weighted MRI before and after neoadjuvant immunochemotherapy. Histogram analysis features (mean, median, and entropy) were extracted from pre- and post-treatment APTw and apparent diffusion coefficient (ADC) maps, respectively.

View Article and Find Full Text PDF

H-F cross-polarization magic angle spinning dynamic nuclear polarization NMR investigation of advanced pharmaceutical formulations.

J Magn Reson

December 2024

Oral Product Development, Pharmaceutical Technology & Development, Operations, AstraZeneca, Gothenburg, Sweden.

A new 3.2 mm H-F-X magic angle spinning dynamic nuclear polarization NMR (MAS DNP-NMR) probe was developed with a unique coil design with separate radiofrequency channels for H excitation and C or F detection to enable acquisition of H-F cross-polarization (CP) MAS experiments, direct-detected F spectra with proton decoupling, and acquisition on C with simultaneous double decoupling on the H and 19F channels as well as H-F-C double-CP experiments under low temperature MAS DNP conditions. We use these sequences to study AZD2811, which is an active pharmaceutical ingredient (API), in its pure dry state as well as in its corresponding drug delivery formulation consisting of drug-loaded polymeric nanoparticles (PNPs).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!