The D allele of the insertion/deletion (I/D) polymorphism of the angiotensin I-converting enzyme (ACE) gene is associated with higher plasma and tissue ACE levels, which enhance the stimulus for neo-intimal hyperplasia. Plaque debulking before stenting reduces the plaque-related determinants of in-stent restenosis and provides an ideal clinical model for studying neointimal hyperplasia. We prospectively studied 113 consecutive patients undergoing elective DCA followed by stent implantation. The presence of I/D in ACE genome DNA was analysed by means of polymerase chain reaction. Follow-up coronary angiography was performed 6-12 months after DCA, and all of the angiograms were quantitatively analysed. The baseline clinical and angiographic characteristics of the patients with a D/D (33%), I/D (52%) and I/I (15%) genotype were well balanced. There were no significant differences in minimal lumen diameter before and after the procedure or at follow-up, and no significant differences in acute gain, late loss or the loss index. Our results indicate that ACE I/D polymorphism does not influence the risk of developing angiographic restenosis in patients undergoing DCA followed by stent implantation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1160/TH03-10-0619 | DOI Listing |
Am J Transplant
January 2025
Erasmus MC Transplant Institute, Division of HPB/Transplant Surgery, Erasmus Medical Centre Rotterdam. Electronic address:
With an increasingly aging population, both end-stage renal disease and peripheral artery disease become more prevalent. Peripheral artery disease is increasingly treated with endovascular procedures. Endovascular stenting of the external iliac artery (EIA) is often considered a contraindication for kidney transplantation, as clamping of the artery could result in possible injuring of the stent.
View Article and Find Full Text PDFEur Stroke J
January 2025
Department of Neuroradiology, University Hospital Basel, Basel, Switzerland.
Background: There are limited therapeutic options in cases of failed reperfusion (modified thrombolysis in cerebral infarction [mTICI] score < 2b) after stent-retriever and/or aspiration based endovascular treatment (EVT) for acute ischemic stroke. Despite the absence of data supporting its use, rescue therapy (balloon angioplasty and/or stent implantation) is often utilized in such cases. Studies are limited to large vessel occlusions, while the outcomes and complications after rescue therapy in medium/distal vessel occlusions (MDVOs) have not been reported.
View Article and Find Full Text PDFJ Int Med Res
January 2025
Department of Surgery, Chonnam National University Hospital, Gwangju, Republic of Korea.
The popliteal artery segment is particularly challenging for endovascular treatment. Stents used for treating popliteal artery lesions are usually associated with an increased risk of stent fracture and re-occlusion. The Supera stent is designed to withstand mechanical stress, with a low risk of fracture.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States.
Current limitations in implant design often lead to trade-offs between minimally invasive surgery and achieving the desired post-implantation functionality. Here, we present an artificial intelligence inverse design paradigm for creating deployable implants as planar and tubular thermal mechanical metamaterials (thermo-metamaterials). These thermo-metamaterial implants exhibit tunable mechanical properties and volume change in response to temperature changes, enabling minimally invasive and personalized surgery.
View Article and Find Full Text PDFA A Pract
January 2025
Department of Anesthesiology, University of Kansas Medical Center, Kansas City, Kansas.
Transcatheter aortic valve replacement (TAVR) is a common treatment for severe aortic stenosis (AS), but it carries the risk of severe complications, including device embolization. We present a case of a TAVR valve embolization into the left ventricular outflow tract (LVOT), diagnosed with transesophageal echocardiography (TEE) shortly after device deployment. The dislodged valve was successfully retrieved from the LVOT into the aorta, flattened, and stabilized with a thoracic endovascular aneurysm repair (TEVAR) stent, enabling the successful implantation of a new TAVR valve.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!