A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of a novel point-of-care enoxaparin monitor with central laboratory anti-Xa levels. | LitMetric

Background: Measurement of enoxaparin's anticoagulant activity has been limited to specialized coagulation laboratories and has been impractical for areas needing rapid results, such as during coronary angioplasty. A new point-of-care device, Rapidpoint ENOX, was recently developed to measure clotting times with enoxaparin use.

Objectives: To correlate ENOX times with anti-Xa levels among patients receiving enoxaparin.

Methods: A total of 166 patients receiving enoxaparin for the prevention of deep venous thrombosis or as treatment during acute coronary syndromes or angioplasty were prospectively studied. Citrated and non-citrated whole-blood (CWB and NCWB) samples were obtained at baseline and peak enoxaparin activity. ENOX times were measured with whole-blood, and the Stachrom anti-Xa assay was performed on the plasma from the remainder of the samples. The Pearson correlation coefficient was used to assess the relationship between these two assays.

Results: There was a strong linear correlation between the ENOX times and the anti-Xa activities for both CWB (r=0.89, p<0.001) and NCWB (r=0.82, p<0.001) when considering all 332 samples (baseline and peak). When baseline samples were excluded, the correlation remained strong for CWB ENOX times and anti-Xa levels (r=0.84, p<0.001), but was only moderate for NCWB (r=0.73, p<0.001). A CWB ENOX time of /=200 s corresponded to anti-Xa levels >/=0.8 IU/ml in 96% (93/96) of patients.

Conclusions: Rapidpoint ENOX times correlate strongly to anti-Xa activities measured by the Stachrom Heparin Assays for citrated whole-blood samples. This novel test can be used for rapid bedside measurements of enoxaparin anticoagulant activity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.thromres.2004.01.006DOI Listing

Publication Analysis

Top Keywords

enox times
12
anti-xa levels
8
times anti-xa
8
patients receiving
8
evaluation novel
4
novel point-of-care
4
enoxaparin
4
point-of-care enoxaparin
4
enoxaparin monitor
4
monitor central
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!