Objectives: Graft failure has been reported when the arterial conduit, such as the internal thoracic artery (ITA) or the right gastroepiploic artery (GEA), is grafted to a lower grade coronary artery stenosis. The shear stress as a significant factor affecting graft patency was compared between the arterial conduit and the saphenous vein graft (SVG) after surgery.

Methods: In 101 patients, 40 ITAs, 27 GEAs and 34 SVGs were examined using a Doppler-tipped guide wire during postoperative angiography. The graft flow volume and shear stress were calculated from velocity and diameter data. The study grafts were classified according to the grade of native coronary artery stenosis: group L had more than 50 up to 75% stenosis, and group H had more than 75% stenosis. Group H consisted of 25 ITAs, 17 GEAs and 21 SVGs, while group L consisted of 15 ITAs, 10 GEAs and 13 SVGs.

Results: In group H, graft flow volume did not significantly differ among the ITA (34+/-11 ml/min), GEA (36+/-16 ml/min) and SVG (41+/-15 ml/min), and graft shear stress significantly (ITA vs. GEA P<0.0001; GEA vs. SVG P<0.01) differed among the ITA (16.0+/-4.8dyn/cm(2)), GEA (9.1+/-3.2dyn/cm(2)) and SVG (4.8+/-1.6dyn/cm(2)). In group L, flow volume was lower (P<0.001) in the ITA (18+/-6 ml/min) and GEA (13+/-8 ml/min) than in the SVG (35+/-16 ml/min), and shear stress was significantly (P<0.001) greater in the ITA (13.7+/-4.9dyn/cm(2)) than the GEA (5.6+/-2.0dyn/cm(2)) or SVG (4.6+/-2.0dyn/cm(2)).

Conclusions: These data suggest that shear stress of the ITA is superior and maintained despite the flow volume being reduced by flow competition. Lower shear stress of the GEA for intermediate stenosis may be associated with the development of conduit failure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejcts.2003.12.039DOI Listing

Publication Analysis

Top Keywords

shear stress
16
arterial conduit
12
coronary artery
12
artery stenosis
12
itas geas
12
stenosis group
12
saphenous vein
8
geas svgs
8
graft flow
8
flow volume
8

Similar Publications

This study examines the behavior of the Casson nanofluid bioconvection flow around a spinning disc under various influences, including gyrotactic microorganisms, multiple slips, and thermal radiation. Notably, it accounts for the reversible nature of the flow and incorporates the esterification process. The aim of this study is to investigate the influence of reversible chemical reactions on the flow behavior of a Casson nanofluid in the presence of bioconvective microorganisms over a spinning disc.

View Article and Find Full Text PDF

Understanding the Importance of the Small Artery Media-Lumen Ratio: Past and Present.

Basic Clin Pharmacol Toxicol

February 2025

Department of Biomedicine, Aarhus University, Aarhus, Denmark.

The media-lumen diameter ratio of small arteries is increased in hypertension, diabetes and obesity. It is likely that both shear stress on the endothelial cells, transmural pressure and smooth muscle cell tone are important for the altered vascular structure. However, the precise interaction and importance of these factors are incompletely understood.

View Article and Find Full Text PDF

Hydraulic fracturing, which forms complex fracture networks, is a common technique for efficiently exploiting low-permeability conglomerate reservoirs. However, the presence of gravel makes conglomerate highly heterogeneous, endowing the deformation, failure, and internal micro-scale fracture expansion mechanisms with uniqueness. The mechanism of fracture expansion when encountering gravel in conglomerate reservoirs remains unclear, challenging the design and effective implementation of hydraulic fracturing.

View Article and Find Full Text PDF

Different approaches are being developed to efficiently produce in vitro platelets from cultured megakaryocytes to meet the constant demand of platelet transfusion and serve for research purposes. Recent works have shown that turbulence and periodic stress can significantly enhance platelet yield. Here we have developed and characterized a platelet production device that takes in account these properties.

View Article and Find Full Text PDF

Biomechanical assessment of ligament maturation after arthroscopic ligament reconstruction of the anterior talofibular ligament.

Orthop Traumatol Surg Res

January 2025

Department of orthopedic surgery, Clinique du Sport, 36 Boulevard Saint-Marcel, 75005 Paris, France.

Background: Many techniques have been described for lateral ankle ligament reconstruction. Although the biomechanical properties of gracilis tendons are different from those of ligaments, the use of a gracilis tendon autograft is a popular option for anatomical reconstruction. Graft maturation and the biomechanical processes over time remain unclear.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!