A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Tonopen measurement of intraocular pressure in mice. | LitMetric

Tonopen measurement of intraocular pressure in mice.

Exp Eye Res

Department of Ophthalmology, University of Texas Health Science Center at San Antonio, 7703 Floyd Curl Drive, M/C 6230, San Antonio, TX 78229-3900, USA.

Published: April 2004

Purpose: To standardize a method of non-invasive measurement of intraocular pressure (IOP) in mice.

Methods: Cannulated-eye study: IOP was measured simultaneously with a Tonopen and by direct cannulation of the vitreous compartment while pressure was manipulated in steps between 10 and 45 mmHg by a saline reservoir via a second vitreal cannula (five mice, one rat). Non-cannulated-eye study: Tonopen and servo-null measurements were performed in independent groups (48 mice) to verify Tonopen measurements in non-cannulated-eyes. Topical brimonidine (0.15%) was used to decrease IOP.

Results: In the rat, there was a similar relationship between Tonopen readings and direct measurements via cannulation of the eye as previously reported. Although readings from mice eyes were higher in variability than those obtained from the rat, the measurements were reproducible and the correlation between the invasive and the non-invasive methods was good (r = 0.97). The IOP lowering effect of brimonidine was detected with Tonopen as well as servo-null measurements (p < 0.001) and the results with both techniques were similar.

Conclusion: The Tonopen can be used for rapid and reproducible measurements of IOP in mice. The method is easy to apply and can provide a useful means for IOP measurement in mouse models of induced ocular hypertension, in knock-out and transgenic mice, or in pharmacological studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.exer.2003.11.018DOI Listing

Publication Analysis

Top Keywords

measurement intraocular
8
intraocular pressure
8
servo-null measurements
8
tonopen
7
mice
6
measurements
6
iop
5
tonopen measurement
4
pressure mice
4
mice purpose
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!