Diaphragms in clinical trials: is clinician fitting necessary?

Contraception

CONRAD, 1611 Kent Street, No. 806, Arlington, VA 22209, USA.

Published: April 2004

Background: The need for fitting a contraceptive diaphragm has recently been questioned in the context of upcoming trials in which the ability of the diaphragm to prevent sexually transmitted infections will be tested. Being able to provide the same size device to all women would greatly simplify supplying the device and training the clinicians, provided that it does not compromise effectiveness.

Methods: Data from studies of Lea's Shield and FemCap, in which all women were sized for a standard diaphragm and half were randomized to use it during the studies, were reanalyzed to determine if it was feasible to give all women in a barrier study the same size diaphragm or, alternatively, to determine if diaphragm size could be predicted using an algorithm of one or more parameters.

Results: If all women received a size 70 diaphragm, rather than being fitted by a clinician, 33.2% would receive the same size that they would have received if they had been fitted by a clinician. If the definition of a "correct" fit were broadened to include one size larger or smaller than what the clinician would have prescribed, 78.0% would be "correctly" fitted. Using an algorithm that considered parity, body weight and other factors did not improve results.

Conclusion: It would be acceptable to conduct a trial in which all women receive a size 70 diaphragm, provided that all women are sized; that safety, effectiveness and acceptability are closely monitored and that study results are stratified by the diaphragm size determined by clinician fitting. It would also be informative to use sized diaphragms as the comparator in studies of new single-size devices.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.contraception.2003.11.006DOI Listing

Publication Analysis

Top Keywords

size diaphragm
12
clinician fitting
8
diaphragm
8
size
8
women sized
8
diaphragm size
8
fitted clinician
8
receive size
8
women
6
clinician
5

Similar Publications

The inertial element of a solid block is commonly used as the proof mass in traditional accelerometers. However, it is challenging to accommodate both the high-density solid-state proof mass and the highly elastic component simultaneously in a miniature sensor, which makes it difficult for the sensors to maintain comparable sensing performance at a miniaturized size. Here, a novel, to the best of our knowledge, liquid metal-based fiber optic accelerometer (LMFOA) is proposed for the first time to meet this requirement.

View Article and Find Full Text PDF

Introduction: Spinal cord injury is a physiological disruption often caused by trauma, leading to severe physical and psychological effects, including irreversible impairment and disability. Cervical injuries, particularly between C1 and C8, are the most severe, potentially causing diaphragm paralysis and requiring mechanical ventilation. Reduced respiratory muscle strength not only affects respiratory function but also significantly impacts voice, speech, and communication, which are crucial for quality of life.

View Article and Find Full Text PDF

Cattail (), a wetland plant, is emerging as a sustainable materials resource. While most of the species are proven to be a fiber-yielding crop, exhibits the broadest leaf size (5-30 mm), yields highest amount of fiber (≈190.9 g), and captures maximum CO (≈1270 g).

View Article and Find Full Text PDF

Heart and lung sharing the same anatomical space are influenced by each other. Spontaneous breathing induces dynamic changes in intrathoracic pressure, impacting cardiac function, particularly the right ventricle. In intensive care units (ICU), mechanical ventilation (MV) and therefore positive end-expiratory pressure (PEEP) are often applied, and this inevitably influences cardiac function.

View Article and Find Full Text PDF

Implantable Passive Sensors for Biomedical Applications.

Sensors (Basel)

December 2024

School of Electrical and Computer Engineering, National Technical University of Athens, 15772 Athens, Greece.

Article Synopsis
  • Implantable sensors are becoming popular for localized and continuous monitoring in medical settings, allowing for early detection and timely interventions.
  • There are two main types of implantable sensors: active, which have more advanced functionalities but require a power source, and passive, which don't need power and offer simpler, smaller designs.
  • This review focuses on passive sensor technologies, discussing their materials, detection methods, clinical applications, advantages over active sensors, and important considerations for their packaging and compatibility with the human body.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!