The kinematics of treadmill locomotion in rats conceived, born, and raised in a hypergravity environment (HG: 2g) until the age of 3 months was investigated for 5 weeks after their exposition to earth's gravity. The locomotor performance of the HG rats (N=7) was compared to that of age-matched control rats (N=8) housed at 1g for the same period. Kinematic analysis of treadmill locomotion was performed up to 35 days of terrestrial life by an optoelectronic motion analyzer (ELITE system). Results showed that the HG rats exhibited a faster locomotor rhythm (increased number of steps/s), walked closer to the ground, and had a more dorsiflexed foot position. Also, HG rats had shorter steps. The data also highlight a fast adaptation to normal gravity since all the locomotor parameters returned to normal values within 3 weeks. The locomotor modifications may be seen as the persistence of a hypergravity-induced posturo-locomotor adaptation in the centrifuge and/or to more functional changes of sensorimotor systems. Because locomotor performance of HG rats is not severely affected, it is concluded that early development of locomotion processes is highly resistant to gravito-inertial changes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S0166-4328(03)00258-4 | DOI Listing |
Int J Exerc Sci
December 2024
Longwood University, Farmville, Virginia, USA.
Unlabelled: To investigate the effects of differing treadmills on impact acceleration and muscle activation.
Methods: 15 males and 7 females (27.8 ± 7.
Sci Rep
January 2025
Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA.
Over 50% of individuals with lower limb loss report a fear of falling and avoiding daily activities partly due to a lack of plantar sensation. Providing direct somatosensory feedback via neural stimulation holds promise for addressing this issue. In this study, three individuals with lower limb loss received a sensory neuroprosthesis (SNP) that provided plantar somatosensory feedback corresponding to prosthesis-floor interactions perceived as arising from the missing foot generated by electrically activating the peripheral nerves in the residuum.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Centre for Interdisciplinary Research in Rehabilitation and Social Integration, Quebec City, QC G1M 2S8, Canada.
Although guidelines are established for performing the six-minute walking test (6MWT), it is not always possible to implement this test in any setting, due to physical and space limitations. Yet, variations in the conditions of the test could be responsible for heterogeneous outcomes. However, the impact of the condition of the 6MWT is not clearly established in literature.
View Article and Find Full Text PDFScand J Med Sci Sports
January 2025
Faculty of Medicine, Health, and Human Sciences, Macquarie University, Sydney, New South Wales, Australia.
Measuring lower extremity impact acceleration is a common strategy to identify runners with increased injury risk. However, existing axial peak tibial acceleration (PTA) thresholds for determining high-impact runners typically rely on small samples or fixed running speeds. This study aimed to describe the distribution of axial PTA among runners at their preferred running speed, determine an appropriate adjustment for investigating impact magnitude at different speeds, and compare biomechanics between runners classified by impact magnitude.
View Article and Find Full Text PDFPLoS One
January 2025
Falls, Balance and Injury Research Centre, Neuroscience Research Australia, Sydney, Australia.
Background: Treadmill belt perturbations have high clinical feasibility for use in perturbation-based training in older people, but their kinematic validity is unclear. This study examined the kinematic validity of treadmill belt accelerations as a surrogate for overground walkway trips during gait in older people.
Methods: Thirty-eight community-dwelling older people were exposed to two unilateral belt accelerations (8 m s-2) whilst walking on a split-belt treadmill and two trips induced by a 14 cm trip-board whilst walking on a walkway with condition presentation randomised.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!