A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pathological analyses of long-term intracoronary Palmaz-Schatz stenting; Is its efficacy permanent? | LitMetric

Background: Angiographic regression of luminal narrowing occurs 6 months to 3 years poststenting. However, after 4 years lesions progressed gradually and late restenosis was observed in 28% of 179 Palmaz-Schatz-stented lesions during the past 10 years. Elucidating its pathogenesis is pivotal to developing preventive strategies.

Methods And Results: Histopathological and immunohistochemical studies were performed in 19 stented coronary arteries obtained from 19 patients autopsied after noncardiac death 2-7 years poststenting. The quality/severity of chronic inflammatory cells (T lymphocytes, macrophages and multinucleated giant cells) infiltration around the stent struts that is observed even in the absence of restenosis depended on the time elapsed from stenting: a) 2 years postprocedure, in spite of angiographic regression during the first year and pathologically expressed as maturation of the neointimal scar, there was chronic inflammatory response evidence: neovascularization and lymphocyte infiltration, b) > or = 3 years: the neointimal smooth muscle cells were sparse with abundant proliferation of collagen fibers. Presence of slight helper/inducer T lymphocytes and mild macrophage infiltration around the stent struts was evident immunohistochemically, c) > or = 4 years: prominent infiltration by lipid-laden macrophages with strong collagen-degrading matrix metalloproteinase immunoreactivity was observed around the struts. In two of these arteries, the surface contacting the stent was focally disrupted and covered by nonocclusive mural thrombi.

Conclusions: Stainless steel stents evoke a remarkable foreign-body inflammatory reaction to the metal. These persistent peri-strut chronic inflammatory cells may accelerate new indolent atherosclerotic changes and consequent plaque vulnerability.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S1054-8807(03)00132-7DOI Listing

Publication Analysis

Top Keywords

chronic inflammatory
12
angiographic regression
8
years poststenting
8
inflammatory cells
8
infiltration stent
8
stent struts
8
years
7
pathological analyses
4
analyses long-term
4
long-term intracoronary
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!