Background: For maximum treatment compliance there is a need to provide asthma patients with devices that suit their particular preferences. The Foradil Certihaler is a novel multi-dose dry powder inhaler developed to increase the choice of devices available.
Objectives: To evaluate the safety and efficacy of formoterol administered via the Foradil Certihaler, or via the single-dose inhaler Foradil Aerolizer.
Methods: This was a randomized, placebo-controlled, double-dummy, incomplete block crossover, dose-ranging and pharmacokinetic study in patients with persistent asthma. Sixty-seven patients (mean 48.0 years) were randomized to formoterol 5, 10, 15 and 30 microg twice daily via the Certihaler, 12 microg formoterol b.i.d. via the Aerolizer, or placebo in four 1-week double-blind treatment periods separated by 1-week single-blind washouts. RESULTS All formoterol doses delivered via the Certihaler or the Aerolizer significantly increased FEV(1) compared with placebo (p < 0.0001). Formoterol demonstrated an onset of action of <3 min. All active treatments were well tolerated. Tremor was the most common adverse event and was more pronounced at high doses. At lower doses the incidence of tremor with the Certihaler was similar to that observed with placebo or the Aerolizer. The pharmacokinetic evaluation comprised 41 patients (mean 45.9 years). Urinary excretion of unchanged formoterol and total formoterol increased with dose delivered via the Certihaler. The optimum dose of formoterol via the Certihaler was 10 microg.
Conclusion: Delivery of formoterol via the Certihaler or Aerolizer combines rapid relief with enduring control and provides convenient bronchodilation in patients with persistent asthma.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1159/000076672 | DOI Listing |
Int J Pharm
January 2025
School of Engineering, Faculty of Science and Engineering, Macquarie University, Sydney, NSW 2109, Australia.
Intranasal drug delivery is a promising non-invasive method for administering both local and systemic medications. While previous studies have extensively investigated the effects of particle size, airflow dynamics, and deposition locations on deposition efficiency, they have not focused on the thickness of deposited particles, which can significantly affect drug dissolution, absorption and therapeutic efficacy. This study investigates the deposition patterns of dry powder particles within the nasal airway, specifically examining how factors such as flow rates, particle size, and particle cohesiveness influence deposition patterns and their thickness.
View Article and Find Full Text PDFComput Struct Biotechnol J
December 2024
Environmental Intelligence Unit, Flemish Institute for Technological Research (VITO), Boeretang 200, Mol 2400, Belgium.
Exposure of lung epithelia to aerosols is omnipresent. Chronic exposure to polluted air is a significant factor in the development of pulmonary diseases, which are among the top global causes of death, including COVID-19, chronic obstructive pulmonary disease, lung cancer, and tuberculosis. As efforts to prevent and treat lung diseases increase, the development of pulmonary drug delivery systems has become a major area of interest.
View Article and Find Full Text PDFBiomacromolecules
January 2025
Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB R3T 2N2, Canada.
As an abundant renewable natural material, starch has attracted unprecedented interest in the biomedical field. Carboxylated starch particles have been investigated for topical hemostasis, but the powder may not provide physical protection or support for wounds. Here, we prepared macroporous cryogel sponges of methacrylated carboxymethyl starch (CM-ST-MA) containing a covalent and a calcium ionic double network.
View Article and Find Full Text PDFPharmaceutics
January 2025
College of Pharmacy, Keimyung University, Daegu 42601, Republic of Korea.
/: Inhaler devices have been developed for the effective delivery of inhaled medications used in the treatment of pulmonary diseases. However, differing operating procedures across the devices can lead to user errors and reduce treatment efficacy, especially when patients use multiple devices simultaneously. To address this, we developed a novel dry powder inhaler (DPI), combining fluticasone propionate (FP), salmeterol xinafoate (SX), and tiotropium bromide (TB) into a single device designed for bioequivalent delivery compared to existing commercial products in an animal model.
View Article and Find Full Text PDFPharmaceutics
January 2025
Department of Pharmaceutical Sciences, University of Connecticut, Storrs, CT 06269, USA.
Dry powder inhalers (DPI's) are becoming increasingly popular due to growing interest in pulmonary drug delivery and their performance is the net result of a series of processes carried out during the formulation development and manufacturing process such as excipient selection, blending, milling, filling, and spray drying. To reach the small airways of the deep lung, the active pharmaceutical ingredients (API) particles need to have an aerodynamic diameter of 1-5 μm to avoid impaction and particle sedimentation in the upper respiratory tract, and due to this small particle size, the powder becomes highly cohesive resulting in poor flow. Therefore, API is usually blended with a coarse carrier to improve flowability, and due to its large size, it is more fluidizable than the micronized drug.