A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Posterior capsule rupture and vitreous loss during phacoemulsification with or without the use of an anterior chamber maintainer. | LitMetric

Purpose: To compare the incidence of posterior capsule rupture and vitreous loss during phacoemulsification with and without the use of an anterior chamber maintainer (ACM) SETTING: Aristotle University Eye Clinic, Thessaloniki, Greece.

Methods: The surgical records of patients who had phacoemulsification by experienced surgeons over a 2-year period were reviewed. The cases were divided into 2 groups: surgery performed without the use of an ACM (no-ACM group) and surgery performed with the use of an ACM (ACM group).

Results: The no-ACM group comprised 231 cases and the ACM group, 312 cases. Posterior capsule rupture occurred in 19 cases (8.22%) and 22 cases (7.05%), respectively. Of the patients with posterior capsule rupture, 6 (31.57%) in the no-ACM group and 16 (72.72%) in the ACM group had vitreous loss and required an anterior vitrectomy; the difference between the 2 groups was statistically significant (P =.03).

Conclusions: The use of an ACM in phacoemulsification provided a consistently deep anterior chamber and approximately the same rate of complications as with a standard technique in the hands of experienced surgeons. However, when posterior capsule rupture occurred, the incidence of vitreous loss was significantly higher in eyes with an ACM.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0886-3350(03)00584-4DOI Listing

Publication Analysis

Top Keywords

posterior capsule
20
capsule rupture
20
vitreous loss
16
anterior chamber
12
no-acm group
12
rupture vitreous
8
loss phacoemulsification
8
phacoemulsification anterior
8
chamber maintainer
8
acm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!