A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Estimating air-bone gaps using auditory steady-state responses. | LitMetric

Estimating air-bone gaps using auditory steady-state responses.

J Am Acad Audiol

Department of Speech Pathology and Audiology, University of Iowa, Iowa City, Iowa 52242, USA.

Published: January 2004

Auditory steady-state responses (ASSR) were recorded using stimuli presented both via air conduction (AC ASSR) and bone conduction (BC ASSR) in 10 normal-hearing subjects with different degrees of simulated conductive hearing losses. The ASSR-estimated ABG (air-bone gap) was compared with the ABG measured using traditional pure-tone audiometric procedures. Reproducibility of the BC ASSR electrophysiological thresholds was also assessed. Additionally, a group of five subjects with profound sensorineural hearing loss was used to establish stimulation levels in which the BC ASSR was contaminated by stimulus artifact. Results of this investigation showed that the ASSR and behavioral ABGs were strongly correlated with each other (r = .81). However, ASSR-estimated ABGs slightly overestimated the magnitude of the behavioral. Reproducibility of the BC ASSR electrophysiological thresholds was good. Data from the five subjects with profound hearing loss, however, demonstrated that the levels where stimulus artifact became problematic were relatively low. This means BC stimulation may be appropriate only for subjects with normal or mildly impaired cochlear sensitivity.

Download full-text PDF

Source
http://dx.doi.org/10.3766/jaaa.15.1.7DOI Listing

Publication Analysis

Top Keywords

auditory steady-state
8
steady-state responses
8
conduction assr
8
reproducibility assr
8
assr electrophysiological
8
electrophysiological thresholds
8
subjects profound
8
hearing loss
8
stimulus artifact
8
assr
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!