Prodrugs of phosphonoformic acid (PFA), an anti-viral agent used clinically as the trisodium salt (foscarnet), are of interest due to the low bioavailability of the parent drug, which severely limits its utility. Neutral PFA triesters are known to be susceptible to P-C bond cleavage under hydrolytic de-esterification conditions, and it was previously found that P,C-dimethyl PFA P-N conjugates with amino acid ethyl esters did not release PFA at pH 7, and could not be fully deprotected under either acid or basic conditions, which led, respectively, to premature cleavage of the P-N linkage (with incomplete deprotection of the PFA ester moiety), or to P-C cleavage. Here we report that novel, fully deprotected PFA-amino acid P-N conjugates 4 can be prepared via coupling of C-methyl PFA dianion 2 with C-ethyl-protected amino acids using aqueous EDC, which gives a stable monoanionic intermediate 3 that resists P-C cleavage during subsequent alkaline deprotection of the two carboxylate ester groups. At 37 degrees C, the resulting new PFA-amino acid (Val, Leu, Phe) conjugates (4a-c) undergo P-N cleavage near neutral pH, cleanly releasing PFA. A kinetic investigation of 4a hydrolysis at pH values 6.7, 7.2, and 8.5 showed that PFA release was first-order in [4a] with respective t(1/2) values of 1.4, 3.8, and 10.6 h.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bmcl.2004.01.016 | DOI Listing |
Pacing Clin Electrophysiol
January 2025
Boston Scientific, Corporation: Electrophysiology Research & Development, Arden Hills, Minnesota, USA.
As pulsed-field ablation (PFA) emerges as a promising therapy for atrial arrhythmias, an understanding of the cellular injury to cardiac tissue is critical to evaluating and interpreting results for each PFA system. This review aims to detail the mechanism of cell death for PFA, compare the cell death mechanism to thermal ablation modalities, clarify common histology markers, detail the progression of PFA lesions from the acute, to subacute, to chronic maturation states, and discuss clinical indicators of PFA lesions.
View Article and Find Full Text PDFRev Port Cardiol
January 2025
Cardiology Department, Hospital Santa Cruz, Centro Hospitalar Lisboa Ocidental, Lisbon, Portugal.
Introduction And Objectives: Pulmonary vein (PV) isolation is one of the cornerstones of rhythm-control therapy for symptomatic atrial fibrillation (AF) patients. Pulsed field ablation (PFA) is a novel ablation modality that involves the application of electrical pulses causing cellular death, and it has preferential tissue specificity. In this study, we aimed to share a one-year single center experience of AF ablation with PFA.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
January 2025
Hôpital Cardiologique du Haut Léveque, CHU de Bordeaux, L'Institut de RYthmologie et modelisation Cardiaque (LIRYC), Université de Bordeaux, Bordeaux, France.
Background: Achieving a durable mitral line block using radiofrequency as a part of an anatomical approach for ablation in patients with persistent atrial fibrillation or for treating peri-mitral flutter has always been challenging due to the complex anatomy of the mitral isthmus. Epicardial ablation via the coronary sinus and the vein of Marshall has been proposed to help create durable lesions. Recently, a novel lattice-tip catheter using pulsed field ablation has shown promising results for creating mitral lines, despite limited data.
View Article and Find Full Text PDFThe circular-shaped PulseSelect™ PFA catheter has demonstrated comparable efficacy to traditional thermal catheter ablation in achieving pulmonary vein isolation (PVI), while preventing thermally mediated complications. However, this catheter does not have any objective parameters to confirm real-time tissue-catheter contact. We report a case in which PVI was achieved through PFA using optimal biplane fluoroscopic angulations which were more useful for accurately assessing and adjusting the position and rotation of the circular catheter electrodes than the conventional fluoroscopic angulations.
View Article and Find Full Text PDFHip Int
January 2025
Department of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada.
Background: Different methods can help to optimise sagittal cup orientation in total hip arthroplasty (THA) based on individual spinopelvic characteristics. This study aimed to: (1) assess how often combined sagittal index (CSI) and hip-spine-classification targets were achieved post THA; (2) compare anteversion/inclination between cups in-/outside optimal CSI zone; and (3) determine association with outcome.
Methods: This is a multicentre, prospective, case-cohort study of 435 primary THA for osteoarthritis (53% females; age: 65 ± 12 years; follow-up: 2.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!