[Biological behavior of polypropylene meshes suitable for intra-abdominal implantation in animal model].

Magy Seb

Pécsi Tudományegyetem Altalános Orvosi Kar Sebészeti Klinika.

Published: October 2003

The expected incisional hernia rate is between 11-20% after laparotomy. Using mesh repair the results of the hernioplasty have recently improved. However the complication of mesh implants--especially in intraperitoneal position--can be life threatening. Additionally the appropriate mesh is expensive. We tried to create a mesh, which can be used intraperitoneally and generates adhesion in the abdominal wall, but keeps the intraabdominal organs adhesion free. Our experiments were divided into four groups. In the first we used different materials to cover the intraperitoneal side of polypropylene mesh. In the second phase three different pore-sized meshes were compared. In the third part the biological behavior of three different material-reduced meshes were investigated. Based on our previous results in the last session we used only silicone membrane protected material-reduced polypropylene meshes to cover the abdominal defects. Our experiments have shown that intraperitoneal implant with silicone-covered Vypro (Ethicon)/Premilene (B. Braun Medical) mesh significantly decreases the formations of adhesion.

Download full-text PDF

Source

Publication Analysis

Top Keywords

polypropylene meshes
8
mesh
6
[biological behavior
4
behavior polypropylene
4
meshes
4
meshes suitable
4
suitable intra-abdominal
4
intra-abdominal implantation
4
implantation animal
4
animal model]
4

Similar Publications

Robot-Assisted Laparoscopic Sacrohysteropexy with Autologous Fascia Lata.

Int Urogynecol J

December 2024

Department of Obstetrics and Gynaecology, Monash University, Clayton, VIC, 3168, Australia.

Introduction And Hypothesis: Autologous fascia lata has been increasingly utilised in pelvic floor reconstructive surgeries such as sacrocolpopexy and sacrohysteropexy. This case highlights sacrohysteropexy with autologous fascia lata as a promising option for women with advanced uterovaginal prolapse who wish to preserve their uterus and avoid synthetic mesh.

Methods: We report the case of a 65-year-old woman with stage 3 pelvic organ prolapse following one forceps and one spontaneous vaginal delivery.

View Article and Find Full Text PDF

The prevalence of POP in women ranges from 30-40%, with 10-20% requiring surgical intervention. Annually, over 225,000 surgical procedures for POP are performed in the United States. The severity of prolapse is assessed using the four-stage POP-Q system, which facilitates clinical research by providing a standardized measure of defect severity.

View Article and Find Full Text PDF

Introduction: In inguinal hernia repair, mesh weight and pore size are used to describe the mesh characteristics. One meta-analysis of laparo-endoscopic inguinal hernia repairs identified 12 prospective randomized controlled trials (RCTs) with 2,909 patients who had all been treated with lightweight (≤ 50 g/m²) or heavyweight (> 70 g/m²) meshes. None of the 12 RCTs gave details of the pore size.

View Article and Find Full Text PDF

Outcomes of porcine small intestinal submucosa mesh compared to polypropylene mesh in laparoscopic transabdominal preperitoneal inguinal hernia repair: a retrospective cohort study.

Surg Endosc

December 2024

Department of Hernia and Abdominal Wall Surgery, Beijing Chaoyang Hospital, Capital Medical University, No. 5 Jingyuan Road, Shijingshan District, Beijing, 100043, People's Republic of China.

Objective: To compare the long-term outcomes of porcine small intestinal submucosa (SIS) mesh and polypropylene (PP) mesh after an laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair.

Background: Mesh-based surgical techniques for inguinal hernia repair are recommended in the guidelines due to the lower rate of recurrence. Biologic meshes (BMs) may have advantages in terms of chronic pain due to the different postoperative remodeling, without the disadvantages of a permanent implant.

View Article and Find Full Text PDF

Bioinspired Janus Mesh with Mechanical Support and Side-specific Biofunctions for Hernia Repair.

Acta Biomater

December 2024

School of Chemistry and Pharmaceutical Engineering, Medical Science and Technology Innovation Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, 250021, China. Electronic address:

Postoperative adhesion (PA) caused by the combination of proteins, inflammatory response and bacterial infection poses substantial challenges for polypropylene meshes (PPMs) based hernioplasty. Herein, inspired by the peritoneum, a Janus PPMs with side-specific functions was developed via a surface-initiated photoiniferter-mediated polymerization technology. A physical barrier composed of zwitterionic polymer brushes (PS) was firstly constructed on the one side of the PPMs, while the polymethacrylic acid (PMAA) brushes acting as the linker for bioactive nanoparticles (HAP) were precisely situated on the opposite surface subsequently.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!