Synthesis and in vitro evaluation of S-acyl-3-thiopropyl prodrugs of Foscarnet.

Bioorg Med Chem

Laboratoire de Chimie Biomoléculaire, UMR 5032, Université Montpellier II,ENSCM, 8 rue de l'Ecole Normale, 34296, Montpellier Cedex 5, France.

Published: March 2004

A new enzyme-labile group called S-acyl-3-thiopropyl group (SATP) has been synthesized from allylic esters of phosphonate. After demonstration of the enzyme-labile character of the SATP in cellular extracts, it has been introduced onto the phosphonate moiety of PFA (Foscarnet) to obtain potential lipophilic prodrugs. To ponder the lipophilicity of the triesters of PFA, esters of monomethylether of polyethyleneglycols and of thioglycerol were introduced on the PFA carboxylate moiety. The SATP groups were introduced in an attempt to deliver PFA after bioactivation inside the cells. The PFA prodrugs were evaluated in vitro for their activity against human immunodeficiency viruses (HIV-1 and HIV-2).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bmc.2004.01.017DOI Listing

Publication Analysis

Top Keywords

pfa
5
synthesis vitro
4
vitro evaluation
4
evaluation s-acyl-3-thiopropyl
4
s-acyl-3-thiopropyl prodrugs
4
prodrugs foscarnet
4
foscarnet enzyme-labile
4
enzyme-labile group
4
group called
4
called s-acyl-3-thiopropyl
4

Similar Publications

Lesion Formation in Cardiac Pulsed-Field Ablation: Acute to Chronic Cellular Level Changes.

Pacing Clin Electrophysiol

January 2025

Boston Scientific, Corporation: Electrophysiology Research & Development, Arden Hills, Minnesota, USA.

As pulsed-field ablation (PFA) emerges as a promising therapy for atrial arrhythmias, an understanding of the cellular injury to cardiac tissue is critical to evaluating and interpreting results for each PFA system. This review aims to detail the mechanism of cell death for PFA, compare the cell death mechanism to thermal ablation modalities, clarify common histology markers, detail the progression of PFA lesions from the acute, to subacute, to chronic maturation states, and discuss clinical indicators of PFA lesions.

View Article and Find Full Text PDF

Introduction And Objectives: Pulmonary vein (PV) isolation is one of the cornerstones of rhythm-control therapy for symptomatic atrial fibrillation (AF) patients. Pulsed field ablation (PFA) is a novel ablation modality that involves the application of electrical pulses causing cellular death, and it has preferential tissue specificity. In this study, we aimed to share a one-year single center experience of AF ablation with PFA.

View Article and Find Full Text PDF

Acute Nonsustained Mitral Isthmus Block Obtained With Sphere-9 Lattice-Tip Catheter Completed With Vein of Marshall Ethanol Infusion.

J Cardiovasc Electrophysiol

January 2025

Hôpital Cardiologique du Haut Léveque, CHU de Bordeaux, L'Institut de RYthmologie et modelisation Cardiaque (LIRYC), Université de Bordeaux, Bordeaux, France.

Background: Achieving a durable mitral line block using radiofrequency as a part of an anatomical approach for ablation in patients with persistent atrial fibrillation or for treating peri-mitral flutter has always been challenging due to the complex anatomy of the mitral isthmus. Epicardial ablation via the coronary sinus and the vein of Marshall has been proposed to help create durable lesions. Recently, a novel lattice-tip catheter using pulsed field ablation has shown promising results for creating mitral lines, despite limited data.

View Article and Find Full Text PDF

The circular-shaped PulseSelect™ PFA catheter has demonstrated comparable efficacy to traditional thermal catheter ablation in achieving pulmonary vein isolation (PVI), while preventing thermally mediated complications. However, this catheter does not have any objective parameters to confirm real-time tissue-catheter contact. We report a case in which PVI was achieved through PFA using optimal biplane fluoroscopic angulations which were more useful for accurately assessing and adjusting the position and rotation of the circular catheter electrodes than the conventional fluoroscopic angulations.

View Article and Find Full Text PDF

Background: Different methods can help to optimise sagittal cup orientation in total hip arthroplasty (THA) based on individual spinopelvic characteristics. This study aimed to: (1) assess how often combined sagittal index (CSI) and hip-spine-classification targets were achieved post THA; (2) compare anteversion/inclination between cups in-/outside optimal CSI zone; and (3) determine association with outcome.

Methods: This is a multicentre, prospective, case-cohort study of 435 primary THA for osteoarthritis (53% females; age: 65 ± 12 years; follow-up: 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!