A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Transmittance of a bioceramic dental restorative material based on calcium aluminate. | LitMetric

This article investigates the transmittance of a new ceramic filling material as a function of time, thickness, wavelength, and addition of pigments. In the hardened state the ceramic material is composed of hydrates, calcium aluminate, and glass fillers. The radiopacity of the investigated material is also measured. The results of the transmittance are compared to a commercial glass ionomer cement (Fuji II) and resin composite (Tetric Ceram). The transmittance increased with time from low values after 1 h to values close to the glass ionomer cements after 1 week. The resin composite had almost twice the transmittance as the calcium aluminate material and the glass ionomer cement. The amount of light passing through the material was dependent on both the sample thickness and the wavelength. Samples of 0.5-mm thickness transmitted almost twice as much as 1-mm-thick samples. Regarding the wavelength, blue light was scattered very effectively (low transmittance), whereas red light was not (high transmittance). Addition of pigments lowered the transmittance. The radiopacity was slightly higher than that of enamel.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.20042DOI Listing

Publication Analysis

Top Keywords

calcium aluminate
12
glass ionomer
12
transmittance
8
thickness wavelength
8
addition pigments
8
ionomer cement
8
resin composite
8
material
6
transmittance bioceramic
4
bioceramic dental
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!