A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of tissue harmonic imaging and contrast upon between observer and test-retest reproducibility of left ventricular ejection fraction measurement in patients with heart failure. | LitMetric

Aims: To investigate the effects of tissue harmonic imaging (THI) and contrast chamber opacification (LVO) upon measurement variability and reproducibility of echocardiographic left ventricular (LV) volume and ejection fraction (EF) measurements in patients with heart failure (HF).

Background: Echocardiography is often used in HF patients to determine LV volumes and EF. However, current echo methods are variable and may not be applicable for repeat testing in individual patients. THI and LVO have both been shown to improve endocardial visualisation, but it remains to be determined whether this results in better measurement reproducibility.

Methods: Thirty-one HF patients and 30 control subjects underwent echocardiography on two separate days. LV volumes were measured under four different imaging conditions: fundamental, THI, LVO and LVO with ECG-triggered Power Doppler. Chamber opacification, pulmonary transit time (PTT), endocardial enhancement, reproducibility and bias were assessed.

Results: Chamber opacification was inferior and the PTT longer in the HF patients. PTT was related to LV volumes, EF, jugular venous pressure and mitral filling pattern. THI improved endocardial visualisation, and although LVO improved endocardial visualisation in the controls, it offered no benefit over THI in the HF patients. LV volumes and EF were different for each method and THI was the least variable method for repeat measurements.

Conclusions: THI improved endocardial visualisation and was the least variable of the techniques. LVO offered no further advantage in patients with HF and thus cannot be routinely advocated and since LV volumes and EF were different for each, these methods are neither comparable nor interchangeable for follow-up assessments.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejheart.2003.09.011DOI Listing

Publication Analysis

Top Keywords

endocardial visualisation
16
chamber opacification
12
improved endocardial
12
tissue harmonic
8
harmonic imaging
8
left ventricular
8
ejection fraction
8
patients
8
patients heart
8
heart failure
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!