Temporary atrial pacing via a triple lumen central venous catheter.

Can J Anaesth

Chiba, Japan. Saitama, Japan.

Published: March 2004

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF03019103DOI Listing

Publication Analysis

Top Keywords

temporary atrial
4
atrial pacing
4
pacing triple
4
triple lumen
4
lumen central
4
central venous
4
venous catheter
4
temporary
1
pacing
1
triple
1

Similar Publications

Background: Atrial infarction is a complication of myocardial infarction with ventricular infarction; however, isolated atrial infarction (IAI) has rarely been reported. Herein, we report a case of IAI associated with sick sinus syndrome and atrial fibrillation (AF).

Case Summary: An 83-year-old woman was brought to the emergency department with a complaint of general malaise.

View Article and Find Full Text PDF

Background: This case report highlights the conduction disorder anomalies associated with dengue infection, particularly bradyarrhythmias due to dysfunction of the sinus node and atrioventricular node, which may require cardiac stimulation such as pacemaker implantation. This case emphasizes the importance of continuous monitoring and the use of additional diagnostic techniques to detect complications in a timely manner.

Case Summary: A 31-year-old male patient was admitted to our institution with symptoms of dyspnoea, orthopnoea, and severe bradycardia.

View Article and Find Full Text PDF

Introduction: A hybrid approach with very high-power short-duration (vHPSD) posteriorly and ablation-index guided HPSD (50 W) anteriorly seems to be an optimal balance between efficiency and effectiveness for point-by-point pulmonary vein isolation (PVI). The aim of the current study is to compare vHPSD/HPSD ablation to cryoballoon ablation (CBA) in patients with symptomatic atrial fibrillation (AF).

Methods And Results: In this retrospective single-center study, we identified 110 consecutive patients who underwent their first PVI with either vHPSD/HPSD (n = 54) or CBA (n = 56).

View Article and Find Full Text PDF

Background: Left ventricular unloading is needed in patients on extracorporeal life support (ECLS) with severely impaired left ventricular contractility to avoid stasis and pulmonary congestion, and to promote LV recovery. The presence of thrombi in the LV precludes the use of conventional active unloading methods such as transaortic microaxial pumps or apical LV vents. We describe placement of a vent cannula via the left atrial appendage (LAA) as a useful bailout option.

View Article and Find Full Text PDF

False Alarms in Wearable Cardioverter Defibrillators-A Relevant Issue or an Insignificant Observation.

J Clin Med

December 2024

Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité (DHZC), Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany.

The wearable cardioverter defibrillator (WCD) has emerged as a valuable tool used for temporary protection from sudden cardiac death. However, since the WCD uses surface electrodes to detect arrhythmias, it is susceptible to inappropriate detection. Although shock conversion rates for the WCD are reported to be high for detected events, its efficacy in clinical practice tends to be degraded by patient noncompliance.

View Article and Find Full Text PDF