44 consecutive patients with confirmed primary hyperparathyroidism (HPT) undergoing surgery were prospectively enrolled in the study. There were 13 (29.5%) men and 31 (70.5%) women with an overall median age of 59 years (range 23-78 years). Prior to successful parathyroidectomy both (99)Tc(m)-sestamibi/(99)Tc(m)-pertechnetate subtraction scintigraphy (SS) and helical CT were performed, and the results of imaging studies were compared against intraoperative findings. Final histopathology showed 40 (90.9%) solitary parathyroid (PT) adenomata (median size 18 mm, range 8-40 mm), that were in an ectopic location in 13 (32.5%) patients. Moreover, 3 (6.8%) patients had multiglandular disease (one patient with two PT adenomata, two patients with PT hyperplasia), while one (2.3%) patient had a PT carcinoma. The sensitivity and positive predictive value were 86.0% and 97.4% for SS, 88.1% and 94.9% for CT, and 100% and 97.4% for the combination of SS and CT, respectively. Calcium and parathyroid hormone (PTH) serum levels, and the mean size of the removed PT glands of patients with false negative results were lower than that of those with true positive results, but the difference was not significant. Among patients with solitary PT tumours (N=41) the sensitivity was 88.1% and 90.3% for SS and CT-scan, respectively. In conclusion, our study confirms the usefulness of SS, which should be the initial test for patients undergoing parathyroidectomy. However, the strategy of performing two tests in each patient with primary HPT could be of limited utility when the initial SS is positive.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1259/bjr/44399050 | DOI Listing |
Background: Second-generation tau tracers for positron emission tomography (PET) show high affinity for paired helical filaments tau deposits characteristic of Alzheimer´s disease and low off-target binding. Differences in their chemical structure though may lead to variations in their regional tau uptake and off-target signal. In this work, we aimed to compare the in-vivo uptake of tau tracers [F]PI-2620 and [F]RO948 in the early stages of the AD continuum.
View Article and Find Full Text PDFAlzheimers Dement
December 2024
Department of Neurology, Mayo Clinic, Rochester, Minnesota, USA.
Nat Commun
October 2024
Center for Alzheimer's and Neurodegenerative Diseases, Peter O'Donnell Jr. Brain Institute, Dallas, TX, US.
Positron Emission Tomography (PET) ligands have advanced Alzheimer's disease (AD) diagnosis and treatment. Using autoradiography and cryo-EM, we identify AD brain tissue with elevated tau burden, purify filaments, and determine the structure of second-generation high avidity PET ligand MK-6240 at 2.31 Å resolution, which bound at a 1:1 ratio within the cleft of tau paired-helical filament (PHF), engaging with glutamine 351, lysine 353, and isoleucine 360.
View Article and Find Full Text PDFJ Cardiovasc Magn Reson
December 2024
Department of Radiology, Section of Pediatric Radiology, Children's Hospital Colorado, University of Colorado Anschutz Medical Campus, 13123 E 16th Ave, Aurora, Colorado 80045, USA; Department of Bioengineering, University of Colorado Anschutz Medical Campus, 12705 E Montview Blvd, Aurora, Colorado 80045, USA. Electronic address:
Background: Aortic dilation is seen in pediatric/young adult patients with bicuspid aortic valve (BAV), and hemodynamic markers to predict aortic dilation are necessary for monitoring. Although promising hemodynamic metrics, such as abnormal wall shear stress (WSS) magnitude, have been proposed for adult BAV patients using four-dimensional (4D) flow cardiovascular magnetic resonance, those for pediatric BAV patients have less frequently been reported, partly due to scarcity of data to define normal WSS range. To circumvent this challenge, this study aims to investigate if a recently proposed 4D flow-based hemodynamic measurement, abnormal flow directionality, is associated with aortic dilation in pediatric/young adult BAV patients.
View Article and Find Full Text PDFJ Cardiovasc Magn Reson
December 2024
Department of Radiology, Leiden University Medical Center (LUMC), Leiden, the Netherlands.
Background: Aortic blood flow characterization by four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) is increasingly performed in aneurysm research. A limited number of studies have established normal values that can aid the recognition of abnormal flow at an early stage. This study aims to establish additional sex-specific and age-dependent reference values for flow-related parameters in a large cohort of healthy adults.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!