AI Article Synopsis

  • Two bacterial strains were labeled and monitored in two field experiments in a shallow aquifer to study their transport, utilizing fluorescent stains for tracking.
  • The study used various enumeration methods, with findings showing consistency across techniques, although minor discrepancies were noted.
  • The real-time data collection improved sampling efficiency and linked bacterial transport to hydrogeological factors, highlighting the method's potential for microbial ecology research.

Article Abstract

Two differentially labeled bacterial strains were monitored in near-real time during two field-scale bacterial transport experiments in a shallow aquifer in July 2000 and July 2001. Comamonas sp. strain DA001 and Acidovorax sp. strain OY-107 were grown and labeled with the vital fluorescent stain TAMRA/SE (5 [and -6]-carboxytetramethylrhodamine, succinimidyl ester) or CFDA/SE (5 [and -6]-carboxyfluorescein diacetate, succinimidyl ester). Fluorescently labeled cells and a conservative bromide tracer were introduced into a suboxic superficial aquifer, followed by groundwater collection from down-gradient multilevel samplers. Cells were enumerated in the field by microplate spectrofluorometry, with confirmatory analyses for selected samples done in the laboratory by epifluorescence microscopy, flow cytometry, and ferrographic capture. There was general agreement in the results from all of the vital-stain-based enumeration methods, with differences ranging from <10% up to 40% for the analysis of identical samples between different tracking methods. Field analysis by microplate spectrofluorometry was robust and efficient, allowing thousands of samples to be analyzed in quadruplicate for both of the injected strains. The near-real-time data acquisition allowed adjustments to the predetermined sampling schedule to be made. The microplate spectrofluorometry data sets for the July 2000 and July 2001 experiments allowed the transport of the injected cells to be related to the site hydrogeology and injection conditions and enabled the assessment of differences in the transport of the two strains. This near-real-time method should prove effective for a number of microbial ecology applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC368306PMC
http://dx.doi.org/10.1128/AEM.70.3.1680-1687.2004DOI Listing

Publication Analysis

Top Keywords

vital fluorescent
8
bacterial strains
8
succinimidyl ester
8
application vital
4
fluorescent staining
4
staining method
4
method simultaneous
4
simultaneous near-real-time
4
near-real-time concentration
4
concentration monitoring
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!