A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of helium and 40% O2 on graded exercise with self-contained breathing apparatus. | LitMetric

Effects of helium and 40% O2 on graded exercise with self-contained breathing apparatus.

Can J Appl Physiol

Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, T6G 2H9.

Published: December 2003

Maximal exercise performance is decreased when breathing from a self-contained breathing apparatus (SCBA), owing to a ventilatory limitation imposed by the increased expiratory resistance. To test the hypothesis that decreasing the density of the breathing gas would improve maximal exercise performance, we studied 15 men during four graded exercise tests with the SCBA. Participants breathed a different gas mixture during each test: normoxia (NOX; 21% O2, 79% N2), hyperoxia (HOX; 40% O2, 60% N2), normoxic helium (HE-OX; 21% O2, 79% He), and hyperoxic helium (HE-HOX; 40% O2, 60% He). Compared to NOX, power output at the ventilatory threshold and at maximal exercise significantly increased with both hyperoxic mixtures. Minute ventilation was increased at peak exercise with both helium mixtures, and maximal aerobic power (VO2max) was significantly increased by 12.9 +/- 5.6%, 10.2 +/- 6.3%, and 21.8 +/- 5.6% with HOX, HE-OX, and HE-HOX, respectively. At peak exercise, the expired breathing resistance imposed by the SCBA was significantly decreased with both helium mixtures, and perceived respiratory distress was lower with HE-HOX. The results show that HE-OX improved maximal exercise performance by minimizing the ventilation limitation. The performance-enhancing effect of HOX may be explained by increased arterial oxygen content. Moreover, HE-HOX appeared to combine the effects of helium and hyperoxia on VO2max.

Download full-text PDF

Source
http://dx.doi.org/10.1139/h03-065DOI Listing

Publication Analysis

Top Keywords

maximal exercise
16
exercise performance
12
effects helium
8
exercise
8
graded exercise
8
self-contained breathing
8
breathing apparatus
8
21% 79%
8
40% 60%
8
peak exercise
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!