A historical review reveals that McBride may have been the first to use a femoral head intramedullary stemmed hip implant. It had a threaded stem and limited use. Eicher may have been the first to develop and use the smooth intramedullary stemmed femoral implant with a calcar collar, which was the forerunner of implants used today. Moore subsequently developed the self-locking intramedullary stemmed femoral implant with a calcar collar. Shortly thereafter, Thompson introduced a similar prosthesis. These four surgeons pioneered the development of the intramedullary stemmed femoral head prosthesis, which has been a key contribution to modern hip reconstruction.

Download full-text PDF

Source

Publication Analysis

Top Keywords

intramedullary stemmed
20
femoral head
12
stemmed femoral
12
head intramedullary
8
femoral implant
8
implant calcar
8
calcar collar
8
femoral
5
intramedullary
5
stemmed
5

Similar Publications

Inferior outcome of stand-alone short versus long tibial stem in revision total knee arthroplasty. A retrospective comparative study with minimum 2 year follow-up.

SICOT J

January 2025

Department of Orthopedic Surgery and Sport Medicine, Croix-Rousse Hospital, FIFA Medical Center of Excellence, 69004 Lyon, France - Université de Lyon, Université Claude Bernard Lyon 1, IFSTTAR, LBMC UMR_T9406, 69622 Lyon, France.

Introduction: Revision Total Knee Arthroplasty (RTKA) is complex, and induced bone loss might endanger implant fixation and joint stability. Intramedullary stems improve fixation throughout stress redistribution. The current study aims to compare the performance of short tibial stems with long tibial stems, investigating their intermediate-term radiographic and survival outcomes in RTKA.

View Article and Find Full Text PDF

Proximal femoral fractures are particularly common in older adults, and cases requiring conversion to total hip arthroplasty may arise because of treatment failure or osteoarthritis. Fractures around the distal screw removal holes can be problematic. This study aimed to analyze the relationship between stem length and femoral stress distribution to determine the optimal stem length.

View Article and Find Full Text PDF

Background: In order to increase the stability of tibial component in total knee arthroplasty (TKA), intramedullary stem extensions (SE) have been developed. The aim of this systematic review and meta-analysis is to address the critical knowledge gap on post-operative outcomes and complications rate comparison between tibial component with SE compared to the tibial component standard configuration (SC) in primary cemented TKA.

Methods: We conducted a comprehensive search of online databases, including Pubmed, Embase, ISI Web of science, Cochrane Library, and Scopus, using the following MeSH terms, (total knee arthroplasty) OR (TKA) OR (total knee replacement) AND (Tibial stem) OR (stem extension) OR (long stem).

View Article and Find Full Text PDF

Use of semi-constrained total knee arthroplasty in gonarthrosis with collateral ligament insufficiency: Clinical and functional outcomes.

Rev Esp Cir Ortop Traumatol

December 2024

Departamento de Traumatología y Cirugía Ortopédica, Hospital Clínico San Carlos, Madrid, España; Departamento de Cirugía, Universidad Complutense, Madrid, España.

Introduction: Achieving stability in total knee arthroplasty (TKA) is crucial for long-term implant survival. In cases of severe deformity or ligament laxity, constrained implants may be required. Traditionally, increasing constraint involved intramedullary stems.

View Article and Find Full Text PDF

Prevalence and clinical impact of radiographic sclerotic lines adjacent to cementless tibial stems in revision total knee arthroplasty: a long-term follow-up study.

Eur J Orthop Surg Traumatol

November 2024

Granovsky Gluskin Orthopedic Division. Sinai Health System, Mount Sinai hospital, University of 476C-1, 600 University Avenue, Toronto, ON, M5G 1X5, Canada.

Article Synopsis
  • Intramedullary stem extensions are added during revision total knee arthroplasty (TKA) to improve component fixation and longevity, often using hybrid fixation methods.
  • The study involved a retrospective review of 153 patients re-evaluating the prevalence and impact of radiographic sclerotic lines at the bone-implant interface over a follow-up period of 15 years.
  • Results showed that while 7.8% of patients had sclerotic lines, they did not significantly affect the rates of aseptic loosening, with a notable long-term survivorship rate of 94.8% free from failure due to loosening.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!