A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

CT screening for lung cancer: suspiciousness of nodules according to size on baseline scans. | LitMetric

Purpose: To assess the frequency with which a particular, possibly optimal work-up of noncalcified nodules less than 5.0 mm in diameter identified on initial computed tomographic (CT) images at baseline screening leads to a diagnosis of malignancy prior to first annual repeat screening, compared with a possibly optimal work-up of larger nodules.

Materials And Methods: Two series of baseline CT screenings in high-risk people were retrospectively reviewed. The first series (n = 1,000) was performed in 1993-1998; the second (n = 1,897), in 1999-2002. In each series, cases in which the largest noncalcified nodule detected was less than 5.0 mm in diameter and those in which it was 5.0-9 mm were reviewed to determine whether diagnostic work-up prior to first annual repeat screening showed or would have shown nodule growth and led or would have led to a diagnosis based on biopsy or surgical specimens.

Results: The frequency with which malignancy was or could have been diagnosed when the largest noncalcified nodule was less than 5.0 mm in diameter was 0 of 378, whereas when the largest noncalcified nodule was 5.0-9 mm in diameter, the frequency was 13 or 14 of 238. If persons with only nodules smaller than 5.0 mm had merely been referred for first annual repeat screening without immediate further work-up, the referrals for such work-up would have been reduced by 54% (from 817 [28%] to 385 [13%] of 2,897).

Conclusion: In modern CT screening for lung cancer at baseline, detected noncalcified nodules smaller than 5.0 mm in diameter do not justify immediate work-up but only annual repeat screening to determine whether interim growth has occurred.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2311030634DOI Listing

Publication Analysis

Top Keywords

annual repeat
16
repeat screening
16
largest noncalcified
12
noncalcified nodule
12
screening lung
8
lung cancer
8
optimal work-up
8
noncalcified nodules
8
prior annual
8
nodules smaller
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!