Using opaquers under direct composite resin veneers: an illustrated review of the technique.

J Esthet Restor Dent

Department of Stomatology, Operative Dentistry Section, Federal University of Santa Catarina, Rua Lauro Linhares, 1075 Sala B, Trinidade, Florianópolis, Santa Catarina 88036-001, Brazil.

Published: May 2004

Unlabelled: In restorative dentistry direct composite resin materials can be used to conservatively resolve many esthetic problems. Opaque resins are often necessary to mask discolorations and/or dark backgrounds when restoring anterior teeth. This article presents a direct composite resin veneer technique using opaquers. Potential problems with the tone of restorations after the use of opaquers are discussed. Advantages, limitations, and the clinical technique are presented. Training, as well as attention to the technique, contributes to an acceptable result.

Clinical Significance: Resinous opaquers can be used as a valid adjunct to the direct composite resin veneer technique when conservatively restoring dark teeth.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1708-8240.2003.tb00306.xDOI Listing

Publication Analysis

Top Keywords

direct composite
16
composite resin
16
resin veneer
8
veneer technique
8
technique
5
opaquers
4
opaquers direct
4
composite
4
resin
4
resin veneers
4

Similar Publications

TiSquantum dots composite carbon nanotubes aerogel with electromagnetic interference shielding effect.

Nanotechnology

January 2025

Institute of Nonlinear Optics, College of Science, JiuJiang University, Jiangxi 334000, People's Republic of China.

Titanium disulfide quantum dots (TiSQDs) has garnered significant research interest due to its distinctive electronic and optical properties. However, the effectiveness of TiSQDs in electromagnetic interference (EMI) shielding is influenced by various factors, including their size, morphology, monodispersity, tunable bandgap, Stokes shift and interfacial effects. In this study, we propose a systematic approach for the synthesis of TiSQDs with small size (3.

View Article and Find Full Text PDF

Microbial activity in the deep continental subsurface is difficult to measure due to low cell densities, low energy fluxes, cryptic elemental cycles and enigmatic metabolisms. Nonetheless, direct access to rare sample sites and sensitive laboratory measurements can be used to better understand the variables that govern microbial life underground. In this study, we sampled fluids from six boreholes at depths ranging from 244 m to 1,478 m below ground at the Sanford Underground Research Facility (SURF), a former goldmine in South Dakota, United States.

View Article and Find Full Text PDF

Purpose Pre-clinical studies have demonstrated direct influences of the autonomic nervous system (ANS) on the immune system. However, it remains unknown if connections between the peripheral ANS and immune system exist in humans and contribute to the development of chronic inflammatory disease. This study had three aims: 1.

View Article and Find Full Text PDF

Osteoarthritis, a major global cause of pain and disability, is driven by the irreversible degradation of hyaline cartilage in joints. Cartilage tissue engineering presents a promising therapeutic avenue, but success hinges on replicating the native physiological environment to guide cellular behavior and generate tissue constructs that mimic natural cartilage. Although electrical stimulation has been shown to enhance chondrogenesis and extracellular matrix production in 2D cultures, the mechanisms underlying these effects remain poorly understood, particularly in 3D models.

View Article and Find Full Text PDF

Background and Hypothesis Triple-negative breast cancer (TNBC) patients are at increased risk for recurrence compared to other subtypes of breast cancer. Previous evidence showed that adiposity may contribute to worsened cancer control. Current measures of obesity, such as body-mass index (BMI), are poor surrogates of adiposity, while visceral-to-subcutaneous adiposity ratio (VSR), which can be measured from routine computed tomography (CT) imaging, is a direct adiposity measure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!