Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: This retrospective study investigated treatment outcomes over 10 years of a new prosthesis design in implant prosthodontics that uses a combined cement- and screw-retained principle.
Materials And Methods: The clinical data of 78 implant-supported prostheses were examined. Each prosthesis incorporated at least 1 screw-retained element and 1 or more cement-retained telescopic units. One hundred twenty-four screw-retained and 161 cement-retained abutments were employed.
Results: Of the 286 implants placed, 5 were lost prior to prosthetic loading and 4 (1.4%) were lost approximately 14 months after loading. Eight (2.8%) abutment screws were retightened and 1 gold prosthetic screw was replaced after 1,372 days following fracture. No accidental dislodgment of any prosthesis occurred.
Discussion: The introduction of a screw retainer into a series of cement retainers permitted the use of weak cement on the telescopic abutments. This facilitated removal when required while preventing accidental dislodgment. Improved equipment and the learning curve decreased the incidence of abutment screw loosening with time.
Conclusion: The ease of retrievability, allied with the security of seating and excellent appearance, makes the combined screw- and cement-retained prosthesis valuable in implant prosthodontics.