A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of basic pharmaceuticals in human serum by hydrophilic interaction capillary electrochromatography. | LitMetric

Hydrophilic interaction capillary electrochromatography (HI-CEC) for the determination of basic pharmaceuticals spiked in human serum is described. The organic modifier content, ionic strength, and pH value of the mobile phase as well as the applied voltage are optimized for separation and elution of these drug analytes. Excellent separation was achieved for drugs using a mobile phase composition of 80% v/v acetonitrile in 100 mM triethylamine phosphate (TEAP) buffer at pH 2.8 with column efficiencies for analytes more than 200,000 plates/m. The samples of human serum spiked with basic drugs were directly injected after a simple acetonitrile treatment. The linear range and reproducibility of these basic drugs using an external and internal standard method were compared. As a result, the reproducibility could be greatly improved by using the internal standard method. Good calibration curves with regression coefficients more than 0.998 in the range of 5-160 microg/mL were observed with the internal standard method. The limits of quantitation, based on standards with acceptable relative standard deviations (RSDs), were below 5 microg/mL. The intra- and inter-day precisions, determined as RSDs, were less than 4.57%.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.200305757DOI Listing

Publication Analysis

Top Keywords

human serum
12
internal standard
12
standard method
12
determination basic
8
basic pharmaceuticals
8
hydrophilic interaction
8
interaction capillary
8
capillary electrochromatography
8
mobile phase
8
basic drugs
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!