Speech with maxillary implant prostheses: ratings of articulation.

J Dent Res

Faculty of Dentistry, McGill University, 3640 University Street, Montreal, Quebec H3A 2B2, Canada.

Published: March 2004

Speech is often perturbed after placement of maxillary implant-retained prostheses. We tested the hypothesis that the rate of speech errors varies with prosthetic design. Thirty edentulous subjects with mandibular implant prostheses entered two within-subject crossover trials. Subjects wore maxillary fixed prostheses and removable long-bar overdentures (Trial 1), or overdentures with and without palates (Trial 2). Test words from a French language speech battery were recorded after each prosthesis had been worn for two months. The percentages of stops, fricatives, and vowels correctly perceived by lay judges were calculated. Subjects produced a significantly higher percentage of sounds correctly with overdentures than with fixed prostheses. Between-treatment differences were significant for stops and fricatives (p < 0.01), but not for vowels. There were no significant differences in error rates between the two overdentures. In conclusion, maxillary implant overdentures with and without palates enable patients to produce more intelligible speech than fixed prostheses.

Download full-text PDF

Source
http://dx.doi.org/10.1177/154405910408300310DOI Listing

Publication Analysis

Top Keywords

fixed prostheses
12
maxillary implant
8
implant prostheses
8
overdentures palates
8
stops fricatives
8
prostheses
6
speech
5
overdentures
5
speech maxillary
4
prostheses ratings
4

Similar Publications

The influence of prosthetic treatments and implant-supported prostheses on posterior mandibular ridge atrophy: a retrospective cohort study.

BMC Oral Health

January 2025

Division of Restorative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billrothgasse 4, Graz, 8010, Austria.

Aims: Bone preservation is a requirement for long-term stability of dental prostheses, which is all the more important in the posterior mandible, given the particular challenges these areas pose to prosthetic treatment. The objective was to investigate the implications of different prostheses on the atrophy of posterior alveolar bone after tooth loss.

Materials And Methods: A total of 457 treatment cases were retrieved from the medical documentation and information network.

View Article and Find Full Text PDF

Objectives: To: 1) analyze possible differences in the CIEDE2000 lightness, chroma and hue of the gingiva at the free gingival margin (FGM) and the middle zone of keratinized gingiva (MZ) between participants with an ISFP in the maxillary anterior region and participants with natural dentition and healthy gums; and 2) examine the perceptibility/acceptability of the differences in CIEDE2000 lightness, chroma and hue and in overall color, using the Euclidean and CIEDE2000 formulae.

Methods: The L*, a* and b* color coordinates were measured in 60 adult participants (30 with an ISFP and 30 with healthy teeth and gums) using a Spectroshade™ Micro spectrophotometer. From these coordinates, the changes in lightness (ΔL'), chroma (ΔC') and hue (ΔH') CIEDE2000 between the participants with and without an ISFP were quantified.

View Article and Find Full Text PDF

Objectives: The aim of this systematic review and network meta-analysis was to compare the flexural strength of provisional fixed dental prostheses (PFDPs) fabricated using different 3D printing technologies, including digital light processing (DLP), stereolithography (SLA), liquid crystal display (LCD), selective laser sintering (SLS), Digital Light Synthesis (DLS), and fused deposition modeling (FDM).

Materials And Methods: A comprehensive literature search was conducted in databases including PubMed, Web of Science, Scopus, and Open Grey up to September 2024. Studies evaluating the flexural strength of PFDPs fabricated by 3D printing systems were included.

View Article and Find Full Text PDF

Background: Anatomically formed healing abutments were suggested in literature to address many of the issues associated with immediate posterior implant insertion such as large extraction sockets that are extremely hard to seal without reflecting the mucoperiosteal flap, extraction sockets anatomy that are not suitable for regular healing abutment placement, and potentially high occlusal stresses when planning a temporary implant supported prothesis to improve the conditioning of supra implant tissue architecture and the emergence profile of the implant supported restorations.

Purpose: To clinically evaluate the peri-implant soft tissue profile of single posterior implant retained restorations and to assess patient related outcomes of the implant restorations that were conditioned immediately by CAD-CAM socket sealing abutments (SSA) versus those conditioned by Titanium (Ti) standard healing abutments (SHA).

Methods: Twenty participants received twenty-two single maxillary immediate implants after flapless minimally invasive tooth extraction and 3D guided implant placement in the posterior area (premolar and molar) and allocated randomly into two groups (n = 11), the intervention group: patients received PEEK SSA and the control group: the patients received Ti SHA.

View Article and Find Full Text PDF

Objective: This study aimed to compare the biomechanics of implant prostheses and peri-implant bone among 6 different mandibular reconstruction models based on patient data involving the use of an upper free-end double-barrel fibula.

Methods: This study was an observational study. Five models were reconstructed using fibular-supported and implant-supported partial dentures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!