[Concept and validation of a simple model of the intrathyroidal iodine kinetics].

Nuklearmedizin

Abteilung für Nuklearmedizin, Klinikum Stadt Hanau, Leimenstr. 20, 63450 Hanau.

Published: February 2004

Unlabelled: AIM of this study is the introduction and validation of a simple model of the intrathyroidal iodine kinetics, designed for optimizing radioiodine therapy planning and dose measurement in a routine clinical setting.

Methods: The new model defines the intrathyroidal iodine kinetics as balance of the thyroidal iodine intake and -excretion, characterized by the two exponential equations A(t) = A(0) * (1-exp(-lambda(1) t)) and A(t) = A(0) * (exp(-lambda(2) t) -1), respectively. A(0) describes the theoretically maximum iodine uptake when the thyroidal iodine excretion is ignored, lambda(1) and lambda(2) represent the constants characterizing the iodine intake and excretion, respectively. The thyroidal iodine content at the time t equals the sum of both functions, which is A(t) = A(0) * (exp(-lambda(2) t)-exp(-lambda(1) t)). In 25 patients with autonomous goiter / nodules (n = 18), Graves' disease (n = 5), or endemic euthyroid goiter (n = 2), the iodine uptake in the thyroid during the radioiodine therapy as fraction of the applied activity was determined daily, with the remaining body covered by a lead shield. On average, 7.2 measurements were performed per patient (minimum 4, maximum 13). With these uptake values, individual regression curves were fitted using the above equation, and the difference between the actual measurements and the corresponding values of the regression curves was determined.

Results: The average deviation of the 179 uptake values from the calculated points of the respective regression curves was only 1.4%. There was no significant difference between the three disease groups. The distribution of the relative deviations during the individual courses was constant, systematic errors were not detected.

Conclusion: Our results suggest that the intrathyroidal iodine kinetics can be precisely described with the model A(t) = A(0) * (exp(-lambda(2) t)-exp(-lambda(1) t)). With only three measurements, the trend of the curve can be calculated, which allows to determine the total radioiodine storage in the thyroid.

Download full-text PDF

Source
http://dx.doi.org/10.1267/nukl04010021DOI Listing

Publication Analysis

Top Keywords

intrathyroidal iodine
16
iodine kinetics
12
thyroidal iodine
12
regression curves
12
iodine
10
validation simple
8
simple model
8
model intrathyroidal
8
radioiodine therapy
8
iodine intake
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!