Purpose: As adhesives containing hydrophilic/acidic resin components are vulnerable to water movement after polymerization, this study tested the hypothesis that coupling of a single-bottle adhesive (OptiBond Solo Plus) to self/dual-cured composites is compromised by adhesive permeability, even with the adjunctive use of chemical co-initiators.
Materials And Methods: Two versions of chemical co-initiators (activators) were investigated: the proprietary resin-containing OptiBond Solo Plus Activator (A), and a resin-free solution of 2% benzene sulphinic acid sodium salt in ethanol (B). For microtensile bond testing, hydrated (H) or dehydrated (D) bonded human dentin were coupled to a dual-cured composite (Bis-Core) under light- (L) or self-activation (C) mode. A delayed light-activation mode (DL) was also employed to simulate the slower rate of polymerization of self-cured composites but without the influence from adverse chemical interaction. Nine groups were tested: 1) L-H (control); 2) DL-H; 3) DL-D; 4) C-H; 5) C-D; 6) CA-H; 7) CA-D; 8) CB-H; and 9) CB-D. For transmission electron microscopy, a light-cured and an experimental self-cured composite of the same composition were used for the nine groups.
Results: Only the bond strength results of the experimental groups DL-D (Group 3) and CB-D (Group 9) were not significantly different from the control group L-H (p > 0.05). TEM revealed the presence of discrete silver-filled water blisters along the adhesive-composite interface in groups 2, 6, and 8, and within the composite in group 4. Adverse chemical interaction in groups 4 and 5 resulted in the observation of a line of silver deposits along the adhesive composite interface.
Conclusion: The coupling of composites after prolonged contact with hydrated dentin bonded with OptiBond Solo Plus is affected by the intrinsic permeability of the adhesive. The adjunctive use of the Activator is only slightly effective in improving the coupling of this adhesive with self/dual-cured composites. Although the use of resin-free benzene sulphinic acid sodium salt solution completely eliminates the adverse chemical interaction, the inherent permeability of the polymerized adhesive precludes optimal coupling of self/dual-cured composites to bonded hydrated dentin.
Download full-text PDF |
Source |
---|
The purpose of this study was to determine the most effective method for bonding composite resin to artificially aged amalgam. A spherical amalgam alloy was triturated and condensed by hand into cylindrical plastic molds (6 mm in diameter and 4 mm in height) to create 90 specimens, which were then aged for 2 weeks in closed plastic containers at 23°C. The amalgam surfaces underwent 1 of 3 surface treatments (n = 30 per treatment): (1) air particle abrasion (APA) with 50-μm aluminum oxide particles applied with a force of 45 psi from a 10-mm distance, followed by rinsing with deionized water for 60 seconds; (2) APA following the same protocol with subsequent application of a metal primer (Alloy Primer); or (3) coating with 30-μm silica (CoJet) at a force of 45 psi from a 10-mm distance until the surface turned black.
View Article and Find Full Text PDFNanomaterials (Basel)
December 2022
College of Dental Medicine, Midwestern University, Glendale, AZ 85308, USA.
Experimental adhesives containing co-doped metaloxide nanoparticles were demonstrated to display strong and long-term antibacterial properties against Streptococcus mutans biofilms. The present study represents an effort to characterize the shear-bond strength (SBS) and color stability (CS) of these novel biomaterials. Experimental adhesives were obtained by dispersing nitrogen and fluorine co-doped titanium dioxide nanoparticles (NF_TiO2, 10%, 20% or 30%, v/v%) into OptiBond Solo Plus (OPTB).
View Article and Find Full Text PDFInt J Environ Res Public Health
December 2022
Department of Orthodontics, Faculty of Dentistry, Mahidol University, Bangkok 10400, Thailand.
Topical anesthetics are commonly used to minimize pain and anxiety during dental procedures. Research is scarce on the influence of topical anesthetics on bond strength. Thus, this research evaluated the effect of dentin contamination by topical anesthetic solution and gel on the micro-shear bond strengths of etch-and-rinse and self-etch bonding systems.
View Article and Find Full Text PDFNanomaterials (Basel)
October 2022
Division of Dental Biomaterials, Department of Restorative Sciences, College of Dentistry, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73117, USA.
Experimental adhesives with functional nitrogen-doped titanium dioxide nanoparticles (N_TiO) have been shown to display improved properties. However, these materials have not been characterized regarding their degree of conversion (DC), biaxial flexure strength (BFS), surface roughness (SR), elastic modulus (EM), and long-term antibacterial functionalities. Experimental adhesives were synthesized by dispersing N_TiO (10%, 20%, or 30%, /%) into OptiBond Solo Plus (OPTB, Kerr Corp.
View Article and Find Full Text PDFEur J Dent
October 2022
Department of Operative Dentistry, Faculty of Dentistry, Thammasat University, Pathumthani, Thailand.
Objectives: This study evaluated the surface microhardness of composite, affected by surface coating with different dental adhesive systems.
Materials And Methods: A total of 100 composite discs were divided into five groups. Group 1 was uncoated (control group C), and groups 2 to 5 were coated with different adhesive systems (OptiBond FL: FL, OptiBond SOLO Plus: SOLO, OptiBond XTR: XTR, and OptiBond All in one: AIO, respectively).