  • The study evaluates a new device called QUISI, which is an ambulatory EEG recording tool, and its effectiveness compared to the traditional polysomnography (PSG) in diagnosing sleep disorders like snoring and obstructive sleep apnoea (OSA).
  • QUISI was tested on 40 patients, revealing that it can identify normal and altered sleep profiles with high sensitivity (0.92) and specificity (0.96), but it tends to underestimate total sleep time and different sleep stages.
  • While QUISI provides valuable insights into sleep architecture, it's not a complete substitute for the more comprehensive PSG performed in sleep labs, indicating limitations in its accuracy for detailed sleep analysis.

Article Abstract

Electroencephalogram (EEG) evaluation with polysomnography (PSG) according to the Rechtschaffen & Kales (R&K) rules is time and cost consumptive, but ambulatory polygraphy systems do not allow EEG recording routinely. As a consequence, the number of sleep disordered events cannot be calculated exactly. QUISI is a one-channel, self-applicable ambulatory EEG recording device. The present study was designed as a prospective, non-randomized clinical trial. This investigation evaluated the results of 40 patients with primary snoring and obstructive sleep apnoea measured with level 1 PSG and QUISI simultaneously. Fifteen patients (37.5%) were primary snorers with normal sleep profiles, whereas 25 patients (62.5%) suffered from obstructive sleep apnoea (OSA) with a Respiratory Disturbance Index (RDI) of 38.6 +/- 23.8. The mean total sleeping time (TST) was underestimated by 4.5%, while Sleep Efficiency Index (SEI) was understimated by 4.6% by the QUISI device compared with PSG. The correlation between the QUISI and the PSG estimates for single sleep stages demonstrated only moderate correlation. The statistical significance for sleep stage 2 was r = 0.42, P = 0.002; for sleep stage 3/4, r = 0.31, P = 0.02; and for WAKE, r = 0.33, P = 0.01. Sleep stage 2 as well as sleep stage 3/4 were underestimated by QUISI substantially (difference: -5.6% and -10.3%), while WAKE was overestimated by QUISI to a larger amount (difference: +10.4%). Sensitivity and specificity of QUISI to recognize pathological sleep profiles compared with PSG/R&K were 0.92 and 0.96 respectively. QUISI is able to evaluate normal versus altered sleep profiles in patients with primary snoring and OSA. Comparing the quartile ranges, we found substantial differences between QUISI and PSG/R&K. QUISI gives an impression of sleep architecture and objective verification of a sleep disturbance in an ambulant setting but cannot replace the sleep laboratory-based PSG.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1365-2273.2004.00759.xDOI Listing

Publication Analysis

Top Keywords

sleep
17
sleep stage
16
primary snoring
12
obstructive sleep
12
sleep apnoea
12
sleep profiles
12
quisi
11
recording device
8
snoring obstructive
8
eeg recording
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!