A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A versatile rapid-mixing and flow device for X-ray absorption spectroscopy. | LitMetric

A versatile rapid-mixing and flow device for X-ray absorption spectroscopy.

J Synchrotron Radiat

Department of BCPS, Illinois Institute of Technology, BioCAT, 435B, APS, ANL, Argonne, IL 60439, USA.

Published: March 2004

A low-temperature rapid-mixing and flow system has been designed and implemented to monitor catalysis involving metal ions by X-ray absorption spectroscopy at the ID-18 beamline of the Advanced Photon Source, Argonne National Laboratory. The system will allow examination of biological metallo-intermediates at dilute metal ion concentrations by the detection of X-ray fluorescence. The instrument can be cooled to sub-zero temperatures, thus lengthening the life time of a reaction intermediate. A portable UV-visible spectrometer is integrated with the flow system to monitor the sample optically. The system can also be used as a continuous-flow device to minimize radiation-induced sample damage by reducing sample exposure to the X-ray beam. The integration of the stop-flow instrument with the synchrotron beamline and X-ray fluorescence detector systems makes it unique for time-resolved X-ray absorption studies of dilute biological reactions. The results of the initial testing of the system are presented.

Download full-text PDF

Source
http://dx.doi.org/10.1107/S0909049503028474DOI Listing

Publication Analysis

Top Keywords

x-ray absorption
12
rapid-mixing flow
8
absorption spectroscopy
8
flow system
8
x-ray fluorescence
8
x-ray
6
system
5
versatile rapid-mixing
4
flow device
4
device x-ray
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!