Determination of plasma homovanillic acid by liquid chromatography with electrochemical detection.

J Chromatogr

Department of Laboratory Medicine, St. Joseph's Hospital, Hamilton, Ontario, Canada.

Published: November 1992

We describe a simple method for extracting homovanillic acid (HVA) from plasma. An aliquot of 0.5 ml of the internal standard solution (3-hydroxy-4-methoxycinnamic acid in 0.2 mol/l phosphoric acid) and 0.5 ml of the sample are applied to a 1-ml Bond Elut C18 column prewashed with methanol and 0.2 mol/l phosphoric acid. The sample is drawn through the column at low speed. The column is washed with water and eluted with dichloromethane. The eluate is evaporated under vacuum at ambient temperature and the residue reconstituted with 250 microliters of the mobile phase. A 10-microliters aliquot of the resulting solution is injected onto a 150 mm x 4.6 mm I.D. column packed with 5-microns octadecylsilyl silica particles (Beckman). Peaks are detected coulometrically in the screening-oxidation mode with E1 = +0.25 V and E2 = +0.38 V. In the resulting chromatogram, HVA and the internal standard give sharp peaks and are well separated from solvent and other endogenous electroactive acids. The extraction recovery is 90-95% which allows the determination of 0.5 microgram/l analyte.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0378-4347(92)80325-kDOI Listing

Publication Analysis

Top Keywords

homovanillic acid
8
internal standard
8
mol/l phosphoric
8
phosphoric acid
8
acid sample
8
acid
5
determination plasma
4
plasma homovanillic
4
acid liquid
4
liquid chromatography
4

Similar Publications

This paper summarizes the main findings of a study which aimed to examine the electrochemical oxidation of homovanillic acid (HVA), the final metabolite of dopamine. A pencil graphite electrode (PGE) was used as working electrode and the measurements were performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The type and the composition of the graphite leads used as PGE, the pH of the supporting electrolyte, as well as the scan rates were optimized by CV.

View Article and Find Full Text PDF

We developed a reversed-phased high-performance liquid chromatographic method combining ultraviolet detection and integrated pulsed amperometric detection for the simultaneous quantification of dopamine, 5-hydroxyindolacetic acid, homovanillic acid, serotonin, 3,4-dihydroxyphenylacetic acid, norepinephrine and epinephrine. All target components were completely separated in a C18 column with isocratic elution of 5% acetonitrile solution containing 8 mM HClO4 and 0.20 mM 1-octanesulfonic acid as an ion pairing reagent.

View Article and Find Full Text PDF

Retroperitoneal teratomas are rare neoplasms in neonates, presenting with nonspecific symptoms and variable clinical features, making diagnosis challenging. Radiological investigations, particularly fetal ultrasound and contrast-enhanced computed tomography, play a critical role in their detection. Differential diagnoses include neuroblastoma, adrenal hemorrhage, and congenital cystic lesions, which share overlapping clinical and imaging features.

View Article and Find Full Text PDF
Article Synopsis
  • A new Sonogel-Carbon (SNGC) electrode, enhanced with the amino acid l-leucine, has been created for detecting homovanillic acid (HVA) effectively.
  • Electrochemical techniques like cyclic voltammetry and impedance spectroscopy confirmed the performance of the SNGC-Leu electrode, which demonstrated a linear detection range for HVA from 0.5 μM to 50 μM and a detection limit of 0.4 μM.
  • The SNGC-Leu sensor showed high accuracy in real applications, successfully measuring HVA in human urine and synthetic cerebrospinal fluid with impressive recovery rates.
View Article and Find Full Text PDF

Biopeptide-rich fermented hemp seeds: Boosting anti-inflammatory and immune responses through Lactiplantibacillus plantarum probiotic fermentation.

Int J Biol Macromol

December 2024

Department of Food Science and Biotechnology, College of Agriculture and Life Sciences, Kangwon National University, Chuncheon, 24341, South Korea; Future F Biotech Co., Ltd, Chuncheon 24341, South Korea. Electronic address:

Article Synopsis
  • Hemp seeds are shown to have anti-inflammatory and immunological benefits, and fermentation with Lactiplantibacillus plantarum enhances these properties.
  • The study found that fermented hemp seed extracts significantly inhibited inflammatory cytokines more effectively than unfermented seeds, indicating a boost of 25% to 39.3% in their effects.
  • Metabolomic analysis identified novel bioactive compounds linked to these enhanced effects, suggesting fermented hemp seeds could be developed into functional food ingredients for health and wellness applications.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?