Computer-aided lens assembly.

Appl Opt

Wolfson School of Mechanical and Manufacturing Engineering, Loughborough University, Ashby Road, Loughborough, Leicestershire, LE11 3TU, United Kingdom.

Published: January 2004

We propose a computer-aided method of lens manufacture that allows assembly, adjustment, and test phases to be run concurrently until an acceptable level of optical performance is reached. Misalignment of elements within a compound lens is determined by a comparison of the results of physical ray tracing by use of an array of Gaussian laser beams with numerically obtained geometric ray traces. An estimate of misalignment errors is made, and individual elements are adjusted in an iterative manner until performance criteria are achieved. The method is illustrated for the alignment of an air-spaced doublet.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.43.000579DOI Listing

Publication Analysis

Top Keywords

computer-aided lens
4
lens assembly
4
assembly propose
4
propose computer-aided
4
computer-aided method
4
method lens
4
lens manufacture
4
manufacture allows
4
allows assembly
4
assembly adjustment
4

Similar Publications

Skin cancer is a significant global health concern, with timely and accurate diagnosis playing a critical role in improving patient outcomes. In recent years, computer-aided diagnosis systems have emerged as powerful tools for automated skin cancer classification, revolutionizing the field of dermatology. This survey analyzes 107 research papers published over the last 18 years, providing a thorough evaluation of advancements in classification techniques, with a focus on the growing integration of computer vision and artificial intelligence (AI) in enhancing diagnostic accuracy and reliability.

View Article and Find Full Text PDF

Vat photopolymerization of multifunctional fresnel lenses for ocular management.

Front Bioeng Biotechnol

October 2024

Department of Mechanical and Nuclear Engineering, Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates.

In this study, multifunctional Fresnel lenses were explored as a potential solution for correcting vision in patients with color vision deficiency (CVD) and high myopia. Current studies have primarily focused on color vision correction through the 3D printing of glasses and contact lenses. However, the potential of 3D-printed multifunctional devices, such as Fresnel lenses, goes beyond addressing a single vision correction issue.

View Article and Find Full Text PDF

Visualization of X-ray fields, overlaps, and over-beaming on surface of the head in spiral computed tomography using computer-aided design-based X-ray beam modeling.

Radiol Phys Technol

October 2024

Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan.

To visualize the X-ray fields, overlaps, and over-beaming on the skin surface during spiral head CT scanning. The measured pitch factors were determined by measuring 3 rotation times, 11 table-feed speeds, and an X-ray beam width. The X-ray fields, overlaps, and over-beaming on the skin surface were calculated via computer-aided design-based X-ray beam modeling, and the values obtained using the nominal pitch and measured pitch factors were compared.

View Article and Find Full Text PDF

Medical image segmentation is a crucial component of computer-aided clinical diagnosis, with state-of-the-art models often being variants of U-Net. Despite their success, these models' skip connections introduce an unnecessary semantic gap between the encoder and decoder, which hinders their ability to achieve the high precision required for clinical applications. Awareness of this semantic gap and its detrimental influences have increased over time.

View Article and Find Full Text PDF

Comparison of trial lens and computer-aided fitting in orthokeratology: A multi-center, randomized, examiner-masked, controlled study.

Cont Lens Anterior Eye

October 2024

Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing, China; Beijing Key Laboratory of Intraocular Tumor Diagnosis and Treatment, Medical Artificial Intelligence Research and Verification Key Laboratory of the Ministry of Industry and Information Technology, Beijing, China. Electronic address:

Article Synopsis
  • The study aimed to assess the effectiveness and safety of traditional vs. computer-aided lens fitting methods for orthokeratology in the Chinese population, involving 280 participants over a year-long period.
  • Participants were randomly assigned to either group, with assessments of visual acuity and other ocular health metrics conducted at the start and after lens use, defining success by specific metrics of visual correction.
  • Results showed that the computer-aided group had a higher success rate for visual correction compared to the traditional group, though both methods had similar outcomes regarding axial length changes and adverse events.
View Article and Find Full Text PDF